Close Go back Collapse all sections
Process Data set: Hot pressing/gluing ; Bamboo, rattan furniture ; Adhesive (solid hot melt) ; Press molding ; All sizes; NESPS2 (en) en zh

Key Data Set Information
Location CN
Reference year 2019
Name
Hot pressing/gluing ; Bamboo, rattan furniture ; Adhesive (solid hot melt) ; Press molding ; All sizes; NESPS2
Use advice for data set This dataset is derived from the Pollution Source Census Report and contains information on pollution emissions and related products. However, it does not include data on energy or chemical consumption, nor does it provide information on waste or co-product generation. When utilizing this dataset, please supplement the missing data based on actual conditions before use
Technical purpose of product or process 本工业过程包括使用热压/胶压技术生产竹制和藤制家具,采用固体热熔胶粘剂进行压制成型,可生产各种尺寸的产品。在环境管理方面,该过程采用了多种末端管控技术来管理挥发性有机化合物(VOCs)的排放。这些技术包括活性炭纤维或沸石吸附/解吸、催化氧化、活性炭吸附/解吸催化燃烧、吸附加蒸汽解吸、低温等离子、光解、一次性活性炭吸附,以及直接排放。每种技术都有相应的技术效率和运行率计算方法。
Classification
Class name : Hierarchy level
  • ILCD: Reference Parameters / Systems / Textiles, furnitures and other interiors
General comment on data set the Technical of end-of-pipe management technology for pollution volatile organic compoundisDirect discharge,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of dust removal equipment (kWh) / (rated power of dust removal equipment (kW) × dust removal equipment operating time (hours))
Copyright No
Owner of data set
Quantitative reference
Reference flow(s)
Technological representativeness
Technology description including background system the Technical of end-of-pipe management technology for pollution volatile organic compoundisDirect discharge,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of dust removal equipment (kWh) / (rated power of dust removal equipment (kW) × dust removal equipment operating time (hours))
LCI method and allocation
Type of data set Unit process, single operation
Data sources, treatment and representativeness
Deviation from data treatment and extrapolations principles / explanations None
Data source(s) used for this data set
Completeness
Completeness of product model No statement
Validation
Type of review
Dependent internal review
Reviewer name and institution
Data generator
Data set generator / modeller
Publication and ownership
UUID 2676b1fa-699b-4cd8-9161-33809264c0d5
Date of last revision 2024-04-15T22:04:15.860492+08:00
Data set version 00.01.005
Permanent data set URI https://lcadata.tiangong.world/showProcess.xhtml?uuid=2676b1fa-699b-4cd8-9161-33809264c0d5&version=01.00.000&stock=TianGong
Owner of data set
Copyright No
License type Free of charge for all users and uses

Inputs

Type of flow Classification Flow Location Mean amount Resulting amount Minimum amount Maximum amount
Product flow
Materials production / Organic chemicals 1.0 kg1.0 kg
General comment nan

Outputs

Type of flow Classification Flow Location Mean amount Resulting amount Minimum amount Maximum amount
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 2.2500000000000002E-4 kg2.2500000000000002E-4 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisOthers (activated carbon fiber or zeolite adsorption/desorption/catalytic oxidation),Its Technical efficiency of end-of-pipe management85,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = operating time of wastewater treatment facilities (hours) / normal production time (hours)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 3.0E-4 kg3.0E-4 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisActivated carbon adsorption/desorption catalytic combustion method,Its Technical efficiency of end-of-pipe management80,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = operating time of wastewater treatment facilities (hours) / normal production time (hours)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 7.5E-4 kg7.5E-4 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisAdsorption + steam desorption,Its Technical efficiency of end-of-pipe management50,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = operating time of wastewater treatment facilities (hours) / normal production time (hours)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.0010500000000000002 kg0.0010500000000000002 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisLow temperature plasma,Its Technical efficiency of end-of-pipe management30,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of dust removal equipment (kWh) / (rated power of dust removal equipment (kW) × dust removal equipment operating time (hours))
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.0012 kg0.0012 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisPhotolysis,Its Technical efficiency of end-of-pipe management20,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of dust removal equipment (kWh) / (rated power of dust removal equipment (kW) × dust removal equipment operating time (hours))
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.00141 kg0.00141 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisOthers (disposable activated carbon adsorption),Its Technical efficiency of end-of-pipe management6
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.0015 kg0.0015 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisDirect discharge,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of dust removal equipment (kWh) / (rated power of dust removal equipment (kW) × dust removal equipment operating time (hours))