Close Go back Collapse all sections
Process Data set: Plant protein drinks ; Almond ; Refining ; All sizes; NESPS2 (en) en zh

Key Data Set Information
Location CN
Reference year 2019
Name
Plant protein drinks ; Almond ; Refining ; All sizes; NESPS2
Use advice for data set This dataset is derived from the Pollution Source Census Report and contains information on pollution emissions and related products. However, it does not include data on energy or chemical consumption, nor does it provide information on waste or co-product generation. When utilizing this dataset, please supplement the missing data based on actual conditions before use
Technical purpose of product or process 本技术流程涉及从杏仁中生产包括精制在内的各种规模的植物蛋白饮料。涉及的尾端管理技术用于控制污染,具体为废水处理。它结合了物理化学处理、厌氧生物处理、好氧生物处理,以及在某些情况下的额外物理处理。此系统确保了诸如化学需氧量、总磷、有机结合氮和氨氮等污染物的处理。这种尾端处理技术的效率根据具体污染物而变化,范围在85%至99%之间。
Classification
Class name : Hierarchy level
  • ILCD: Reference Parameters / Materials production / Food and renewable raw materials
General comment on data set the Technical of end-of-pipe management technology for pollution chemical oxygen demandisPhysicochemical treatment + anaerobic biological treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management97,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Copyright No
Owner of data set
Quantitative reference
Reference flow(s)
Technological representativeness
Technology description including background system the Technical of end-of-pipe management technology for pollution chemical oxygen demandisPhysicochemical treatment + anaerobic biological treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management97,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
LCI method and allocation
Type of data set Unit process, single operation
Data sources, treatment and representativeness
Deviation from data treatment and extrapolations principles / explanations None
Data source(s) used for this data set
Completeness
Completeness of product model No statement
Validation
Type of review
Dependent internal review
Reviewer name and institution
Data generator
Data set generator / modeller
Publication and ownership
UUID 26fe1e7d-e4aa-4093-a51e-47a3197c3611
Date of last revision 2024-04-15T22:04:17.926960+08:00
Data set version 00.01.005
Permanent data set URI https://lcadata.tiangong.world/showProcess.xhtml?uuid=26fe1e7d-e4aa-4093-a51e-47a3197c3611&version=01.00.000&stock=TianGong
Owner of data set
Copyright No
License type Free of charge for all users and uses

Inputs

Outputs

Type of flow Classification Flow Location Mean amount Resulting amount Minimum amount Maximum amount
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 4.24E-4 kg4.24E-4 kg
General comment the Technical of end-of-pipe management technology for pollution phosphorus, totalisPhysicochemical treatment + anaerobic biological treatment + aerobic biological treatment + physical treatment,Its Technical efficiency of end-of-pipe management96,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 6.36E-4 kg6.36E-4 kg
General comment the Technical of end-of-pipe management technology for pollution phosphorus, totalisPhysicochemical treatment + anaerobic biological treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management94
Product flow
Materials production / Food and renewable raw materials 1000.0 kg1000.0 kg
General comment nan
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.001812 kg0.001812 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen, organic boundisPhysicochemical treatment + anaerobic biological treatment + aerobic biological treatment + physical treatment,Its Technical efficiency of end-of-pipe management98,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
2300.0 2300.0
General comment the Technical of end-of-pipe management technology for pollution Waste wateris/,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.002718 kg0.002718 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen, organic boundisPhysicochemical treatment + anaerobic biological treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management97,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
0.004521 0.004521
General comment the Technical of end-of-pipe management technology for pollution Ammonia NitrogenisPhysicochemical treatment + anaerobic biological treatment + aerobic biological treatment + physical treatment,Its Technical efficiency of end-of-pipe management89,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual power consumption of wastewater treatment facilities (kWh) / (total rated power (kW) × annual operating time (hours))
0.006165 0.006165
General comment the Technical of end-of-pipe management technology for pollution Ammonia NitrogenisPhysicochemical treatment + anaerobic biological treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management85,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual power consumption of wastewater treatment facilities (kWh) / (total rated power (kW) × annual operating time (hours))
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.0598 kg0.0598 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisPhysicochemical treatment + anaerobic biological treatment + aerobic biological treatment + physical treatment,Its Technical efficiency of end-of-pipe management99,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = operating time of wastewater terminal treatment facilities (hours) / normal production time (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.1794 kg0.1794 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisPhysicochemical treatment + anaerobic biological treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management97,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /