Close Go back Collapse all sections
Process Data set: Unit drying ; Fiberboard ; Fiber, adhesive (water-based) ; Pipeline drying ; All sizes; NESPS2 (en) en zh

Key Data Set Information
Location CN
Reference year 2019
Name
Unit drying ; Fiberboard ; Fiber, adhesive (water-based) ; Pipeline drying ; All sizes; NESPS2
Use advice for data set This dataset is derived from the Pollution Source Census Report and contains information on pollution emissions and related products. However, it does not include data on energy or chemical consumption, nor does it provide information on waste or co-product generation. When utilizing this dataset, please supplement the missing data based on actual conditions before use
Technical purpose of product or process 提供的生命周期评估数据描述了干燥纤维板材料的过程,其中纤维和水性胶粘剂使用管道方法干燥,适用于所有规模的操作。数据还详细介绍了用于治理挥发性有机化合物(VOCs)污染的各种末端治理技术,包括活性炭纤维或沸石吸附/脱附/催化氧化、活性炭吸附/脱附催化燃烧、吸附加蒸汽脱附、低温等离子体、光解、一次性活性炭吸附和直接排放。
Classification
Class name : Hierarchy level
  • ILCD: Reference Parameters / Materials production / Other materials
General comment on data set the treatment technology for the pollution of Exhaust gasdidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of dust removal equipment (kWh) / (rated power of dust removal equipment (kW) × dust removal equipment operating time (hours))
Copyright No
Owner of data set
Quantitative reference
Reference flow(s)
Technological representativeness
Technology description including background system the treatment technology for the pollution of Exhaust gasdidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of dust removal equipment (kWh) / (rated power of dust removal equipment (kW) × dust removal equipment operating time (hours))
LCI method and allocation
Type of data set Unit process, single operation
Data sources, treatment and representativeness
Deviation from data treatment and extrapolations principles / explanations None
Data source(s) used for this data set
Completeness
Completeness of product model No statement
Validation
Type of review
Dependent internal review
Reviewer name and institution
Data generator
Data set generator / modeller
Publication and ownership
UUID 2a4fdd25-1585-40eb-b875-32a989873135
Date of last revision 2024-04-15T22:04:21.822677+08:00
Data set version 00.01.005
Permanent data set URI https://lcadata.tiangong.world/showProcess.xhtml?uuid=2a4fdd25-1585-40eb-b875-32a989873135&version=01.00.000&stock=TianGong
Owner of data set
Copyright No
License type Free of charge for all users and uses

Inputs

Outputs

Type of flow Classification Flow Location Mean amount Resulting amount Minimum amount Maximum amount
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 8.25E-5 kg8.25E-5 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisOthers (activated carbon fiber or zeolite adsorption/desorption/catalytic oxidation),Its Technical efficiency of end-of-pipe management85,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of dust removal equipment (kWh) / (rated power of dust removal equipment (kW) × dust removal equipment operating time (hours))
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 1.1E-4 kg1.1E-4 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisActivated carbon adsorption/desorption catalytic combustion method,Its Technical efficiency of end-of-pipe management80,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of dust removal equipment (kWh) / (rated power of dust removal equipment (kW) × dust removal equipment operating time (hours))
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 2.75E-4 kg2.75E-4 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisAdsorption + steam desorption,Its Technical efficiency of end-of-pipe management50
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 3.8500000000000003E-4 kg3.8500000000000003E-4 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisLow temperature plasma,Its Technical efficiency of end-of-pipe management30
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 4.4E-4 kg4.4E-4 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisPhotolysis,Its Technical efficiency of end-of-pipe management20,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of dust removal equipment (kWh) / (rated power of dust removal equipment (kW) × dust removal equipment operating time (hours))
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 5.17E-4 kg5.17E-4 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisOthers (disposable activated carbon adsorption),Its Technical efficiency of end-of-pipe management6,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of dust removal equipment (kWh) / (rated power of dust removal equipment (kW) × dust removal equipment operating time (hours))
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 5.5E-4 kg5.5E-4 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisDirect discharge,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of dust removal equipment (kWh) / (rated power of dust removal equipment (kW) × dust removal equipment operating time (hours))
Product flow
Materials production / Wood 1.0 kg1.0 kg
General comment nan
Product flow
Materials production / Inorganic chemicals 21.6 m321.6 m3
General comment the treatment technology for the pollution of Exhaust gasdidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of dust removal equipment (kWh) / (rated power of dust removal equipment (kW) × dust removal equipment operating time (hours))