Process Data set: Casting ; Casting ; Pig iron, steel scrap, ferroalloy, intermediate alloy ingot, limestone, carbon enhancer, electrolytic copper ; All sizes; NESPS2 (en) en zh

Key Data Set Information
Location CN
Reference year 2019
Name
Casting ; Casting ; Pig iron, steel scrap, ferroalloy, intermediate alloy ingot, limestone, carbon enhancer, electrolytic copper ; All sizes; NESPS2
Use advice for data set This dataset is derived from the Pollution Source Census Report and contains information on pollution emissions and related products. However, it does not include data on energy or chemical consumption, nor does it provide information on waste or co-product generation. When utilizing this dataset, please supplement the missing data based on actual conditions before use
Technical purpose of product or process 所提及的材料在铸造过程中被用于制造各类铁、钢和铜产品。该过程涉及使用感应炉或电阻炉等设备熔化生铁、废钢、铁合金、中间合金锭和电解铜,并加入石灰石和增碳剂以提炼最终产品。产品适用于汽车、建筑、航空航天和机械制造等各个行业。为了管理PM2.5至PM10范围内的污染颗粒,采用了板式静电除尘器、管式过滤、袋式过滤器、文丘里系统、喷雾塔、水冲击浴、多管旋风除尘和单筒旋风系统等尾气处理技术,确保了环境合规并减少了颗粒物的排放。
Classification
Class name : Hierarchy level
  • ILCD: Reference Parameters / Materials production / Metals and semimetals
General comment on data set the treatment technology for the pollution of Exhaust gasdidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
Copyright No
Owner of data set
Quantitative reference
Reference flow(s)
Technological representativeness
Technology description including background system the treatment technology for the pollution of Exhaust gasdidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
LCI method and allocation
Type of data set Unit process, single operation
Data sources, treatment and representativeness
Deviation from data treatment and extrapolations principles / explanations None
Data source(s) used for this data set
Completeness
Completeness of product model No statement
Validation
Type of review
Dependent internal review
Reviewer name and institution
Data generator
Data set generator / modeller
Publication and ownership
UUID 3efd930c-8a21-49f0-a097-22027966f2ab
Date of last revision 2024-04-15T22:04:56.185759+08:00
Data set version 00.01.005
Permanent data set URI https://lcadata.tiangong.world/showProcess.xhtml?uuid=3efd930c-8a21-49f0-a097-22027966f2ab&version=01.00.000&stock=TianGong
Owner of data set
Copyright No
License type Free of charge for all users and uses

Inputs

Outputs

Type of flow Classification Flow Location Mean amount Resulting amount Minimum amount Maximum amount
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.02395 kg0.02395 kg
General comment the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isBag filter,Its Technical efficiency of end-of-pipe management95,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.02395 kg0.02395 kg
General comment the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isPlate electrostatic precipitator,Its Technical efficiency of end-of-pipe management95,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.02395 kg0.02395 kg
General comment the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isTubular filtration,Its Technical efficiency of end-of-pipe management95
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.07185 kg0.07185 kg
General comment the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isSpray tower/water shock bath,Its Technical efficiency of end-of-pipe management85,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.07185 kg0.07185 kg
General comment the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isVenturi,Its Technical efficiency of end-of-pipe management85,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.1437 kg0.1437 kg
General comment the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isMulti-tube cyclone dust removal,Its Technical efficiency of end-of-pipe management70,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.1916 kg0.1916 kg
General comment the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isSingle cylinder (multiple cylinders in parallel) cyclone,Its Technical efficiency of end-of-pipe management60
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.479 kg0.479 kg
General comment the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isDirect discharge,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Product flow
Materials production / Other materials 1000.0 kg1000.0 kg
General comment nan
Product flow
Materials production / Inorganic chemicals 7483.0 m37483.0 m3
General comment the treatment technology for the pollution of Exhaust gasdidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)