Close Go back Collapse all sections
Process Data set: Product Drying ; Wooden doors and windows, wooden stairs, solid wood flooring, solid wood laminate flooring, other wood products (wooden containers, cork products) ; Coatings, Adhesives ; Leveling/drying/are-drying ; All sizes; NESPS2 (en) en zh

Key Data Set Information
Location CN
Reference year 2019
Name
Product Drying ; Wooden doors and windows, wooden stairs, solid wood flooring, solid wood laminate flooring, other wood products (wooden containers, cork products) ; Coatings, Adhesives ; Leveling/drying/are-drying ; All sizes; NESPS2
Use advice for data set This dataset is derived from the Pollution Source Census Report and contains information on pollution emissions and related products. However, it does not include data on energy or chemical consumption, nor does it provide information on waste or co-product generation. When utilizing this dataset, please supplement the missing data based on actual conditions before use
Technical purpose of product or process 本工艺过程涉及木制门窗、木楼梯、实木地板、实木复合地板及其他木制品(木制容器、软木制品)等多种木制品的干燥处理。在整个生产规模中,都会使用到涂料和胶粘剂,并进行流平、烘干和风干处理。此过程配备了末端治理技术,以减轻挥发性有机化合物(VOCs)的污染。这些技术包括活性炭纤维或沸石吸附/脱附/催化氧化、活性炭吸附/脱附催化燃烧、加蒸汽脱附的吸附技术、低温等离子、光解以及一次性活性炭吸附。提及了废气直排,但没有指定治理技术。
Classification
Class name : Hierarchy level
  • ILCD: Reference Parameters / Energy carriers and technologies / Heat and steam
General comment on data set the treatment technology for the pollution of Exhaust gasdidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of process waste gas purification device (kWh) / (rated power of process waste gas purification device (kW) × process waste gas purification device operating time (hours))
Copyright No
Owner of data set
Quantitative reference
Reference flow(s)
Technological representativeness
Technology description including background system the treatment technology for the pollution of Exhaust gasdidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of process waste gas purification device (kWh) / (rated power of process waste gas purification device (kW) × process waste gas purification device operating time (hours))
LCI method and allocation
Type of data set Unit process, single operation
Data sources, treatment and representativeness
Deviation from data treatment and extrapolations principles / explanations None
Data source(s) used for this data set
Completeness
Completeness of product model No statement
Validation
Type of review
Dependent internal review
Reviewer name and institution
Data generator
Data set generator / modeller
Publication and ownership
UUID 6acf3549-c174-44f4-b0ef-41316da56d9d
Date of last revision 2024-04-15T22:06:25.725881+08:00
Data set version 00.01.005
Permanent data set URI https://lcadata.tiangong.world/showProcess.xhtml?uuid=6acf3549-c174-44f4-b0ef-41316da56d9d&version=01.00.000&stock=TianGong
Owner of data set
Copyright No
License type Free of charge for all users and uses

Inputs

Outputs

Type of flow Classification Flow Location Mean amount Resulting amount Minimum amount Maximum amount
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 3.8700000000000003E-4 kg3.8700000000000003E-4 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisOthers (activated carbon fiber or zeolite adsorption/desorption/catalytic oxidation),Its Technical efficiency of end-of-pipe management85,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = operating time of wastewater treatment facilities (hours) / normal production time (hours)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 5.160000000000001E-4 kg5.160000000000001E-4 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisActivated carbon adsorption/desorption catalytic combustion method,Its Technical efficiency of end-of-pipe management80
Product flow
Systems / Construction 1.0 m31.0 m3
General comment nan
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.0012900000000000001 kg0.0012900000000000001 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisAdsorption + steam desorption,Its Technical efficiency of end-of-pipe management50,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of process waste gas purification device (kWh) / (rated power of process waste gas purification device (kW) × process waste gas purification device operating time (hours))
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.001806 kg0.001806 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisLow temperature plasma,Its Technical efficiency of end-of-pipe management30,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = operating time of wastewater treatment facilities (hours) / normal production time (hours)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.0020640000000000003 kg0.0020640000000000003 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisPhotolysis,Its Technical efficiency of end-of-pipe management20,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = operating time of wastewater treatment facilities (hours) / normal production time (hours)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.0024251999999999998 kg0.0024251999999999998 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisOthers (disposable activated carbon adsorption),Its Technical efficiency of end-of-pipe management6,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = operating time of wastewater treatment facilities (hours) / normal production time (hours)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.0025800000000000003 kg0.0025800000000000003 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisDirect discharge
Product flow
Materials production / Inorganic chemicals 78.9 m378.9 m3
General comment the treatment technology for the pollution of Exhaust gasdidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of process waste gas purification device (kWh) / (rated power of process waste gas purification device (kW) × process waste gas purification device operating time (hours))