Close Go back Collapse all sections
Process Data set: Calcination ; Anode carbon block for aluminum ; Petroleum coke, coal pitch, etc. ; Calcination (natural gas) ; All sizes; NESPS2 (en) en zh

Key Data Set Information
Location CN
Reference year 2019
Name
Calcination ; Anode carbon block for aluminum ; Petroleum coke, coal pitch, etc. ; Calcination (natural gas) ; All sizes; NESPS2
Use advice for data set This dataset is derived from the Pollution Source Census Report and contains information on pollution emissions and related products. However, it does not include data on energy or chemical consumption, nor does it provide information on waste or co-product generation. When utilizing this dataset, please supplement the missing data based on actual conditions before use
Technical purpose of product or process 通过使用天然气的煅烧工艺生产的阳极碳块,主要由石油焦和煤沥青等材料制成,广泛应用于铝冶炼行业。此产品对通过电解过程生产铝至关重要。排放处理末端技术包括用于净化颗粒物(PM2.5 - PM10)的喷雾技术结合静电沉淀,以及用于二氧化硫(SO2)减排的石灰石/石膏法,这些技术应用于减少该过程的排放,通过高达98.5%的颗粒物去除效率和95%的二氧化硫去除效率,确保遵守环境法规。
Classification
Class name : Hierarchy level
  • ILCD: Reference Parameters / Energy carriers and technologies / Heat and steam
General comment on data set the treatment technology for the pollution of Exhaust gasdidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
Copyright No
Owner of data set
Quantitative reference
Reference flow(s)
Technological representativeness
Technology description including background system the treatment technology for the pollution of Exhaust gasdidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
LCI method and allocation
Type of data set Unit process, single operation
Data sources, treatment and representativeness
Deviation from data treatment and extrapolations principles / explanations None
Data source(s) used for this data set
Completeness
Completeness of product model No statement
Validation
Type of review
Dependent internal review
Reviewer name and institution
Data generator
Data set generator / modeller
Publication and ownership
UUID 72167744-4d57-4b2c-a851-d0b03f9a3e2b
Date of last revision 2024-04-15T22:06:45.674812+08:00
Data set version 00.01.005
Permanent data set URI https://lcadata.tiangong.world/showProcess.xhtml?uuid=72167744-4d57-4b2c-a851-d0b03f9a3e2b&version=01.00.000&stock=TianGong
Owner of data set
Copyright No
License type Free of charge for all users and uses

Inputs

Outputs

Type of flow Classification Flow Location Mean amount Resulting amount Minimum amount Maximum amount
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.09105 kg0.09105 kg
General comment the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isOthers (spray + electrostatic precipitation),Its Technical efficiency of end-of-pipe management98.5,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.09105 kg0.09105 kg
General comment the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isOthers (spray + electrostatic precipitation),Its Technical efficiency of end-of-pipe management98.5,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.425 kg0.425 kg
General comment the Technical of end-of-pipe management technology for pollution sulfur dioxideisLimestone/gypsum method,Its Technical efficiency of end-of-pipe management95
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.425 kg0.425 kg
General comment the Technical of end-of-pipe management technology for pollution sulfur dioxideisLimestone/gypsum method,Its Technical efficiency of end-of-pipe management95,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.54 kg0.54 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen oxidesisDirect discharge,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.54 kg0.54 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen oxidesisDirect discharge,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
Product flow
Materials production / Metals and semimetals 1000.0 kg1000.0 kg
General comment nan
2560.0 2560.0
General comment the treatment technology for the pollution of Waste waterdidn't offered
2560.0 2560.0
General comment the treatment technology for the pollution of Waste waterdidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
Product flow
Materials production / Inorganic chemicals 2980.0 m32980.0 m3
General comment the treatment technology for the pollution of Exhaust gasdidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Product flow
Materials production / Inorganic chemicals 2980.0 m32980.0 m3
General comment the treatment technology for the pollution of Exhaust gasdidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)