Close Go back Collapse all sections
Process Data set: Remediated soil ; In-situ soil remediation ; In-situ Multiphase Extraction (en) en zh

Key Data Set Information
Location BE
Geographical representativeness description SRI Biochim is a 2 ha site located in the 250 ha industrial zone of Vilvoorde-Machelen just north east of Brussels.
Reference year 2015
Name
Remediated soil ; In-situ soil remediation ; In-situ Multiphase Extraction
Use advice for data set When utilizing the Life Cycle Assessment data for the in-situ Multiphase Extraction process, it is essential to incorporate the operational duration of the MPE system, which is conservatively estimated at 15 years. Note the requirement for replacement of some components within this timeframe. It's crucial to account for all primary raw materials and the essential energy consumption in the input-output flow calculations. The functional unit for this data set is the removal of an estimated 80% of contaminants from approximately 40,000 cubic meters of subsurface soil, which should be factored into the overall assessment.
Technical purpose of product or process The technical usage of the described industrial process is primarily for in-situ soil remediation. Specifically, the multiphase extraction method is applied to contaminated land areas. It serves to effectively extract contaminant masses, such as soil vapor and non-aqueous phase liquids, from a large volume of subsurface soil, thereby returning the land to a non-hazardous state suitable for future use or redevelopment.
Classification
Class name : Hierarchy level
  • ILCD: Unit processes / Other Services / Repair and maintenance
General comment on data set In-situ Multiphase Extraction (MPE) is a remediation technology that extracts soil vapor, non-aqueous phase liquids and groundwater simultaneously. The vacuum extraction allows liquid flow rates to be increased around the extraction well, due to the increased pressure gradient from the groundwater being drawn downward. Lowering the pressure around the well in the subsurface also allows the non-aqueous phase liquid to volatilize more easily. The volatilized contaminants are removed from the subsurface via extraction wells. The extracted soil vapor, non-aqueous phase liquids and groundwater are treated on the surface via gas and liquid treatment trains.
Copyright No
Owner of data set
Quantitative reference
Reference flow(s)
Functional Unit The functional unit in this study is the removal of approximately 80% of the estimated 500 metric tons of contaminant mass from a subsurface soil volume of approximately 40,000 cubic meters and can be achieved.
Time representativeness
Time representativeness description Publication time of literature
Technological representativeness
Technology description including background system The duration of treatment and total energy budget of the MPE system have been calculated based on the pilot study performed on the SRI Biochim site. The MPE system will require 15 years of operation, which is a conservative estimation. Some of the on-site components and parts that make up the soil vapor and groundwater treatment train will need to be replaced within the 15 years.
Flow diagram(s) or picture(s)
  • ATtRbuaY6oSK8uxHK6DcfYVqn5b.png Image
LCI method and allocation
Type of data set Unit process, black box
Deviation from LCI method principle / explanations None
Deviation from modelling constants / explanations None
Data sources, treatment and representativeness
Deviation from data cut-off and completeness principles / explanations None
Deviation from data selection and combination principles / explanations None
Deviation from data treatment and extrapolations principles / explanations None
Data source(s) used for this data set
Completeness
Completeness of product model No statement
Validation
Type of review
Dependent internal review
Reviewer name and institution
Data generator
Data set generator / modeller
Data entry by
Time stamp (last saved) 2024-03-25T15:51:51+08:00
Publication and ownership
UUID 7f19db59-835c-490d-9128-79a1e2696fa3
Date of last revision 2024-04-20T15:03:39.503898+08:00
Data set version 00.01.005
Permanent data set URI https://lcadata.tiangong.world/showProcess.xhtml?uuid=7f19db59-835c-490d-9128-79a1e2696fa3&version=01.00.000&stock=TianGong
Owner of data set
Copyright No
License type Free of charge for all users and uses

Inputs

Type of flow Classification Flow Location Mean amount Resulting amount Minimum amount Maximum amount
Product flow
Materials production / Plastics 3930.25 kg3930.25 kg
General comment For 3m Extraction wells, the amount of original useage is3.95t. Percentage of service life consumedis 0.995
Product flow
Materials production / Plastics 4185.567 kg4185.567 kg
General comment For 5m Extraction wells, the amount of original useage is4.2066t. Percentage of service life consumedis 0.995
Product flow
Materials production / Plastics 167.16 kg167.16 kg
General comment For Well screens, the amount of original useage is0.168t. Percentage of service life consumedis 0.995
Elementary flow
Resources / Resources from ground / Non-renewable material resources from ground 1057.088 kg1057.088 kg
General comment For Well caps, the amount of original useage is1.0624t. Percentage of service life consumedis 0.995
Product flow
Materials production / Plastics 5.686425E8 kg5.686425E8 kg
General comment For piping, the amount of original useage is571500t. Percentage of service life consumedis 0.995
Product flow
Materials production / Metals and semimetals 0.0 kg0.0 kg
General comment For Pump and knockout tank unit Type A (2 rotary vane pumps per unit), the amount of original useage is0.41t. Percentage of service life consumedis 0
Product flow
Materials production / Metals and semimetals 0.0 kg0.0 kg
General comment For Pump and knockout tank unit Type B  (2 rotary vane pumps per unit), the amount of original useage is0.5t. Percentage of service life consumedis 0
Product flow
Materials production / Metals and semimetals 6666.0 kg6666.0 kg
General comment For Catalytic Oxidation Unit (CATOX), the amount of original useage is20t. Percentage of service life consumedis 0.3333
Product flow
Materials production / Metals and semimetals 3832.95 kg3832.95 kg
General comment For Gas Washer, the amount of original useage is11.5t. Percentage of service life consumedis 0.3333
Product flow
Materials production / Metals and semimetals 833.25 kg833.25 kg
General comment For Quencher, the amount of original useage is2.5t. Percentage of service life consumedis 0.3333
Product flow
Materials production / Metals and semimetals 64.9935 kg64.9935 kg
General comment For Blower, the amount of original useage is0.195t. Percentage of service life consumedis 0.3333
Product flow
Materials production / Metals and semimetals 0.0 kg0.0 kg
General comment For Droplet Separator, the amount of original useage is0.1687t. Percentage of service life consumedis 0
Product flow
Materials production / Metals and semimetals 0.0 kg0.0 kg
General comment For Pump on droplet separator, the amount of original useage is0.0185t. Percentage of service life consumedis 0
Product flow
Materials production / Inorganic chemicals 1610.0 kg1610.0 kg
General comment For Oil and water separator (including coalesces), the amount of original useage is3.22t. Percentage of service life consumedis 0.5
Product flow
Materials production / Raw materials 149.985 kg149.985 kg
General comment For Double walled storage tank, the amount of original useage is0.45t. Percentage of service life consumedis 0.3333
Product flow
Materials production / Metals and semimetals 543.9456 kg543.9456 kg
General comment For Granular Activated Carbon (GAC) vessel for gas-phase treatment, the amount of original useage is1.632t. Percentage of service life consumedis 0.3333
Product flow
Materials production / Metals and semimetals 371.96279999999996 kg371.96279999999996 kg
General comment For Granular Activated Carbon vessel (GAC) for liquid-phase treatment, the amount of original useage is1.116t. Percentage of service life consumedis 0.3333
Product flow
Materials production / Plastics 691.2642 kg691.2642 kg
General comment For Stripping tower (including packing material), the amount of original useage is2.074t. Percentage of service life consumedis 0.3333
Product flow Materials production / Raw materials 1042000.0 kg1042000.0 kg
Product flow Wastes / Production residues 810.0 kg810.0 kg
Product flow
Materials production / Inorganic chemicals 375.71999999999997 kg375.71999999999997 kg
General comment Sodium Hydroxide used as 20% solution is 1 .8786 ton
Product flow
Transport services / Other transport 143870.597 t*km143870.597 t*km
General comment The assembly transported to the site from various manufacturers
Product flow
Transport services / Other transport 668.0 t*km668.0 t*km
General comment Transport of NAPL sludge in double walled storage tank
Product flow Energy carriers and technologies / Electricity 1.29329136E7 MJ1.29329136E7 MJ
Product flow Energy carriers and technologies / Crude oil based fuels 0.24 kg0.24 kg
Product flow Materials production / Other materials 7.708E7 m37.708E7 m3

Outputs

Type of flow Classification Flow Location Mean amount Resulting amount Minimum amount Maximum amount
Product flow Materials production / Other materials 7.708E7 m37.708E7 m3