Close Go back Collapse all sections
Process Data set: Chloroacetic acid, phenol ; Synthesis ; All sizes; NESPS2 (en) en zh

Key Data Set Information
Location CN
Reference year 2019
Name
Chloroacetic acid, phenol ; Synthesis ; All sizes; NESPS2
Use advice for data set This dataset is derived from the Pollution Source Census Report and contains information on pollution emissions and related products. However, it does not include data on energy or chemical consumption, nor does it provide information on waste or co-product generation. When utilizing this dataset, please supplement the missing data based on actual conditions before use
Technical purpose of product or process 所描述的工艺包括氯乙酸和苯酚的合成,这些化合物可以在所有规模的工业生产中使用。这些化学品通常应用于制造除草剂、药品和合成树脂等。所引用的末端处理技术涉及各种污水处理技术,如氧化还原过程、厌氧水解、生物过滤、及与A/O过程结合的成型厌氧反应器,以及含有吸收、吸附和脱附的废气和挥发性有机化合物的处理策略。
Classification
Class name : Hierarchy level
  • ILCD: Reference Parameters / Materials production / Organic chemicals
General comment on data set the Technical of end-of-pipe management technology for pollution Ammonia NitrogenisRedox process + anaerobic hydrolysis + biological filter,Its Technical efficiency of end-of-pipe management70,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Copyright No
Owner of data set
Quantitative reference
Reference flow(s)
  • - 1000.0 * 1.0 kg (Mass)
Technological representativeness
Technology description including background system the Technical of end-of-pipe management technology for pollution Ammonia NitrogenisRedox process + anaerobic hydrolysis + biological filter,Its Technical efficiency of end-of-pipe management70,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
LCI method and allocation
Type of data set Unit process, single operation
Data sources, treatment and representativeness
Deviation from data treatment and extrapolations principles / explanations None
Data source(s) used for this data set
Completeness
Completeness of product model No statement
Validation
Type of review
Dependent internal review
Reviewer name and institution
Data generator
Data set generator / modeller
Publication and ownership
UUID 9d75d9d9-6b32-46ab-99f4-59295d150840
Date of last revision 2024-04-15T22:08:34.940377+08:00
Data set version 00.01.005
Permanent data set URI https://lcadata.tiangong.world/showProcess.xhtml?uuid=9d75d9d9-6b32-46ab-99f4-59295d150840&version=01.00.000&stock=TianGong
Owner of data set
Copyright No
License type Free of charge for all users and uses

Inputs

Outputs

Type of flow Classification Flow Location Mean amount Resulting amount Minimum amount Maximum amount
Product flow
Materials production / Organic chemicals 1000.0 kg1000.0 kg
General comment nan
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 4.92 kg4.92 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundis(Absorption + diversion) + (adsorption + steam desorption)/(adsorption + nitrogen/air desorption),Its Technical efficiency of end-of-pipe management97,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual power consumption of wastewater treatment facilities (kWh) / (total rated power (kW) × annual operating time (hours))
66000.0 66000.0
General comment the Technical of end-of-pipe management technology for pollution Waste wateris/,Its Technical efficiency of end-of-pipe management0,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 1.1360000000000001 kg1.1360000000000001 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisRedox process + anaerobic hydrolysis + biological filter,Its Technical efficiency of end-of-pipe management96,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 3.124 kg3.124 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisShaped anaerobic reactor + A/O process,Its Technical efficiency of end-of-pipe management89,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 6.57 kg6.57 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen, organic boundisShaped anaerobic reactor + A/O process,Its Technical efficiency of end-of-pipe management90,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 8.541 kg8.541 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen, organic boundisRedox process + anaerobic hydrolysis + biological filter,Its Technical efficiency of end-of-pipe management87,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Product flow
Materials production / Inorganic chemicals 13000.0 m313000.0 m3
General comment the Technical of end-of-pipe management technology for pollution Exhaust gasis/,Its Technical efficiency of end-of-pipe management0,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = operating time of wastewater terminal treatment facilities (hours) / normal production time (hours)
16.632 16.632
General comment the Technical of end-of-pipe management technology for pollution Ammonia NitrogenisShaped anaerobic reactor + A/O process,Its Technical efficiency of end-of-pipe management72,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
17.82 17.82
General comment the Technical of end-of-pipe management technology for pollution Ammonia NitrogenisRedox process + anaerobic hydrolysis + biological filter,Its Technical efficiency of end-of-pipe management70,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /