Close Go back Collapse all sections
Process Data set: Natural gas ; Coal bed methane ; Drainage and pressure reduction desorption ; All sizes; NESPS2 (en) en zh

Key Data Set Information
Location CN
Reference year 2019
Name
Natural gas ; Coal bed methane ; Drainage and pressure reduction desorption ; All sizes; NESPS2
Use advice for data set This dataset is derived from the Pollution Source Census Report and contains information on pollution emissions and related products. However, it does not include data on energy or chemical consumption, nor does it provide information on waste or co-product generation. When utilizing this dataset, please supplement the missing data based on actual conditions before use
Technical purpose of product or process 所提供的数据集描述了用于处理天然气和煤层气开采过程中污染的各种管端管理技术。这些技术适用于工业部门中的化学需氧量、氨氮、有机氮、石油相关废物和废水的处理。技术包括物理、化学处理方法、回注、先进氧化、絮凝与固液分离、断点氯化、使用BAF曝气过滤器的生化过滤,以及生物活性炭过滤。它们旨在管理并减少污染物,以满足环境标准,并且与环境保护和污染控制设施(特别是化学和石化工业)相关。
Classification
Class name : Hierarchy level
  • ILCD: Reference Parameters / Energy carriers and technologies / Natural gas based fuels
General comment on data set the Technical of end-of-pipe management technology for pollution chemical oxygen demandisCoagulation and flocculation + advanced oxidation + biological activated carbon filtration,Its Technical efficiency of end-of-pipe management65,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = actual operating hours of environmental protection facilities (hours) / hours that environmental protection facilities should operate (hours)
Copyright No
Owner of data set
Quantitative reference
Reference flow(s)
Technological representativeness
Technology description including background system the Technical of end-of-pipe management technology for pollution chemical oxygen demandisCoagulation and flocculation + advanced oxidation + biological activated carbon filtration,Its Technical efficiency of end-of-pipe management65,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = actual operating hours of environmental protection facilities (hours) / hours that environmental protection facilities should operate (hours)
LCI method and allocation
Type of data set Unit process, single operation
Data sources, treatment and representativeness
Deviation from data treatment and extrapolations principles / explanations None
Data source(s) used for this data set
Completeness
Completeness of product model No statement
Validation
Type of review
Dependent internal review
Reviewer name and institution
Data generator
Data set generator / modeller
Publication and ownership
UUID a3e1719b-fc88-4af6-8249-4af6253e67ef
Date of last revision 2024-04-15T22:08:51.793481+08:00
Data set version 00.01.005
Permanent data set URI https://lcadata.tiangong.world/showProcess.xhtml?uuid=a3e1719b-fc88-4af6-8249-4af6253e67ef&version=01.00.000&stock=TianGong
Owner of data set
Copyright No
License type Free of charge for all users and uses

Inputs

Outputs

Type of flow Classification Flow Location Mean amount Resulting amount Minimum amount Maximum amount
0.0 0.0
General comment the Technical of end-of-pipe management technology for pollution Ammonia NitrogenisPhysical + chemical + reinjection,Its Technical efficiency of end-of-pipe management100,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = actual operating hours of environmental protection facilities (hours) / hours that environmental protection facilities should operate (hours)
0.0 0.0
General comment the Technical of end-of-pipe management technology for pollution Ammonia NitrogenisPhysical + reinjection,Its Technical efficiency of end-of-pipe management100
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.0 kg0.0 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisPhysical + chemical + reinjection,Its Technical efficiency of end-of-pipe management100,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = actual operating hours of environmental protection facilities (hours) / hours that environmental protection facilities should operate (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.0 kg0.0 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisPhysical + reinjection,Its Technical efficiency of end-of-pipe management100
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.0 kg0.0 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen, organic boundisPhysical + chemical + reinjection,Its Technical efficiency of end-of-pipe management100
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.0 kg0.0 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen, organic boundisPhysical + reinjection,Its Technical efficiency of end-of-pipe management100,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = actual operating hours of environmental protection facilities (hours) / hours that environmental protection facilities should operate (hours)
Product flow
Emissions / Other substance type 0.0 kg0.0 kg
General comment the Technical of end-of-pipe management technology for pollution Petroleum-related wasteisPhysical + chemical + reinjection,Its Technical efficiency of end-of-pipe management100
Product flow
Emissions / Other substance type 0.0 kg0.0 kg
General comment the Technical of end-of-pipe management technology for pollution Petroleum-related wasteisPhysical + reinjection,Its Technical efficiency of end-of-pipe management100,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = actual operating hours of environmental protection facilities (hours) / hours that environmental protection facilities should operate (hours)
Product flow
Materials production / Other mineralic materials 10000.0 kg10000.0 kg
General comment nan
Product flow
Emissions / Other substance type 0.0108 kg0.0108 kg
General comment the Technical of end-of-pipe management technology for pollution Petroleum-related wasteisBiochemical method + BAF aeration filter,Its Technical efficiency of end-of-pipe management60,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = actual operating hours of environmental protection facilities (hours) / hours that environmental protection facilities should operate (hours)
Product flow
Emissions / Other substance type 0.0108 kg0.0108 kg
General comment the Technical of end-of-pipe management technology for pollution Petroleum-related wasteisCoagulation and flocculation + advanced oxidation + biological activated carbon filtration,Its Technical efficiency of end-of-pipe management60,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = actual operating hours of environmental protection facilities (hours) / hours that environmental protection facilities should operate (hours)
Product flow
Emissions / Other substance type 0.01161 kg0.01161 kg
General comment the Technical of end-of-pipe management technology for pollution Petroleum-related wasteisAdvanced oxidation + flocculation and solid-liquid separation + breakpoint chlorination,Its Technical efficiency of end-of-pipe management57,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = actual operating hours of environmental protection facilities (hours) / hours that environmental protection facilities should operate (hours)
0.032159999999999994 0.032159999999999994
General comment the Technical of end-of-pipe management technology for pollution Ammonia NitrogenisAdvanced oxidation + flocculation and solid-liquid separation + breakpoint chlorination,Its Technical efficiency of end-of-pipe management94,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = actual operating hours of environmental protection facilities (hours) / hours that environmental protection facilities should operate (hours)
75000.0 75000.0
General comment the treatment technology for the pollution of Waste waterdidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = actual operating hours of environmental protection facilities (hours) / hours that environmental protection facilities should operate (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.07821 kg0.07821 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen, organic boundisAdvanced oxidation + flocculation and solid-liquid separation + breakpoint chlorination,Its Technical efficiency of end-of-pipe management89,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = actual operating hours of environmental protection facilities (hours) / hours that environmental protection facilities should operate (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.09243000000000001 kg0.09243000000000001 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen, organic boundisBiochemical method + BAF aeration filter,Its Technical efficiency of end-of-pipe management87
0.23048 0.23048
General comment the Technical of end-of-pipe management technology for pollution Ammonia NitrogenisBiochemical method + BAF aeration filter,Its Technical efficiency of end-of-pipe management57
0.25727999999999995 0.25727999999999995
General comment the Technical of end-of-pipe management technology for pollution Ammonia NitrogenisCoagulation and flocculation + advanced oxidation + biological activated carbon filtration,Its Technical efficiency of end-of-pipe management52,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = actual operating hours of environmental protection facilities (hours) / hours that environmental protection facilities should operate (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.30573 kg0.30573 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen, organic boundisCoagulation and flocculation + advanced oxidation + biological activated carbon filtration,Its Technical efficiency of end-of-pipe management57,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = actual operating hours of environmental protection facilities (hours) / hours that environmental protection facilities should operate (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 1.14796 kg1.14796 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisAdvanced oxidation + flocculation and solid-liquid separation + breakpoint chlorination,Its Technical efficiency of end-of-pipe management89,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = actual operating hours of environmental protection facilities (hours) / hours that environmental protection facilities should operate (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 2.19156 kg2.19156 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisBiochemical method + BAF aeration filter,Its Technical efficiency of end-of-pipe management79
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 3.6526 kg3.6526 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisCoagulation and flocculation + advanced oxidation + biological activated carbon filtration,Its Technical efficiency of end-of-pipe management65,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = actual operating hours of environmental protection facilities (hours) / hours that environmental protection facilities should operate (hours)