Close Go back Collapse all sections
Process Data set: Ethamethoxam, isopropylmethoxam, butachlor ; Ether method/methylidene method ; All sizes; NESPS2 (en) en zh

Key Data Set Information
Location CN
Reference year 2019
Name
Ethamethoxam, isopropylmethoxam, butachlor ; Ether method/methylidene method ; All sizes; NESPS2
Use advice for data set This dataset is derived from the Pollution Source Census Report and contains information on pollution emissions and related products. However, it does not include data on energy or chemical consumption, nor does it provide information on waste or co-product generation. When utilizing this dataset, please supplement the missing data based on actual conditions before use
Technical purpose of product or process 所描述的工业过程包括各种除草剂(例如乙草胺、异丙甲草胺、丁草胺)和其他相关化学物质的制造和处理。这些物质通常用于农业,以保护作物免受杂草和害虫的侵害。该过程包括使用醚法或甲叉法的生产阶段,并适用于所有规模的操作规模。此外,它还包括使用尾端处理技术来处理废水排放,特别是在环境释放之前,目标是减少废水中的污染物,如化学需氧量(COD)、氨氮、有机结合氮和总磷。
Classification
Class name : Hierarchy level
  • ILCD: Reference Parameters / Materials production / Organic chemicals
General comment on data set the Technical of end-of-pipe management technology for pollution chemical oxygen demandisElectrolysis + (1700 others) deamination tower + chemical coagulation + A2/O process,Its Technical efficiency of end-of-pipe management97,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Copyright No
Owner of data set
Quantitative reference
Reference flow(s)
Technological representativeness
Technology description including background system the Technical of end-of-pipe management technology for pollution chemical oxygen demandisElectrolysis + (1700 others) deamination tower + chemical coagulation + A2/O process,Its Technical efficiency of end-of-pipe management97,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
LCI method and allocation
Type of data set Unit process, single operation
Data sources, treatment and representativeness
Deviation from data treatment and extrapolations principles / explanations None
Data source(s) used for this data set
Completeness
Completeness of product model No statement
Validation
Type of review
Dependent internal review
Reviewer name and institution
Data generator
Data set generator / modeller
Publication and ownership
UUID adc952d6-c554-49f2-ae99-30a633d4c8b3
Date of last revision 2024-04-15T22:09:15.746889+08:00
Data set version 00.01.005
Permanent data set URI https://lcadata.tiangong.world/showProcess.xhtml?uuid=adc952d6-c554-49f2-ae99-30a633d4c8b3&version=01.00.000&stock=TianGong
Owner of data set
Copyright No
License type Free of charge for all users and uses

Inputs

Outputs

Type of flow Classification Flow Location Mean amount Resulting amount Minimum amount Maximum amount
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 8.0E-5 kg8.0E-5 kg
General comment the Technical of end-of-pipe management technology for pollution phosphorus, totalisElectrolysis + (1700 others) deamination tower + chemical coagulation + A2/O process,Its Technical efficiency of end-of-pipe management92
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 1.7E-4 kg1.7E-4 kg
General comment the Technical of end-of-pipe management technology for pollution phosphorus, totalisChemical coagulation + anaerobic hydrolysis + A/O process + redox process,Its Technical efficiency of end-of-pipe management83,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Product flow
Materials production / Organic chemicals 1000.0 kg1000.0 kg
General comment nan
9000.0 9000.0
General comment the Technical of end-of-pipe management technology for pollution Waste wateris/,Its Technical efficiency of end-of-pipe management0
0.017140000000000002 0.017140000000000002
General comment the Technical of end-of-pipe management technology for pollution Ammonia NitrogenisElectrolysis + (1700 others) deamination tower + chemical coagulation + A2/O process,Its Technical efficiency of end-of-pipe management98,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.0903 kg0.0903 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen, organic boundisChemical coagulation + anaerobic hydrolysis + A/O process + redox process,Its Technical efficiency of end-of-pipe management93,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
0.12855000000000003 0.12855000000000003
General comment the Technical of end-of-pipe management technology for pollution Ammonia NitrogenisChemical coagulation + anaerobic hydrolysis + A/O process + redox process,Its Technical efficiency of end-of-pipe management85,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.1419 kg0.1419 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen, organic boundisElectrolysis + (1700 others) deamination tower + chemical coagulation + A2/O process,Its Technical efficiency of end-of-pipe management89,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.586 kg0.586 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisChemical coagulation + anaerobic hydrolysis + A/O process + redox process,Its Technical efficiency of end-of-pipe management98,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.879 kg0.879 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisElectrolysis + (1700 others) deamination tower + chemical coagulation + A2/O process,Its Technical efficiency of end-of-pipe management97,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /