Close Go back Collapse all sections
Process Data set: Post-press finishing ; Printed products (substrate is paper), printed products (substrate is plastic), printed products (substrate is metal), printed products (other substrates) ; Coating solution (solvent-based) ; All finishing processes after printing ; All sizes; NESPS2 (en) en zh

Key Data Set Information
Location CN
Reference year 2019
Name
Post-press finishing ; Printed products (substrate is paper), printed products (substrate is plastic), printed products (substrate is metal), printed products (other substrates) ; Coating solution (solvent-based) ; All finishing processes after printing ; All sizes; NESPS2
Use advice for data set This dataset is derived from the Pollution Source Census Report and contains information on pollution emissions and related products. However, it does not include data on energy or chemical consumption, nor does it provide information on waste or co-product generation. When utilizing this dataset, please supplement the missing data based on actual conditions before use
Technical purpose of product or process 所描述的工业过程涉及印刷行业的印后整理,包括在纸张、塑料、金属和其他材料等不同承印物上应用溶剂型涂布液。此过程适用于所有规模的印后整理操作。它用于通过应用保护性和/或功能性层来提高印刷材料的质量和耐用性。
Classification
Class name : Hierarchy level
  • ILCD: Reference Parameters / Materials production / Paper and cardboards
General comment on data set the treatment technology for the pollution of volatile organic compounddidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Copyright No
Owner of data set
Quantitative reference
Reference flow(s)
Technological representativeness
Technology description including background system the treatment technology for the pollution of volatile organic compounddidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
LCI method and allocation
Type of data set Unit process, single operation
Data sources, treatment and representativeness
Deviation from data treatment and extrapolations principles / explanations None
Data source(s) used for this data set
Completeness
Completeness of product model No statement
Validation
Type of review
Dependent internal review
Reviewer name and institution
Data generator
Data set generator / modeller
Publication and ownership
UUID e016e98c-bf0b-441f-882e-aa08eed3e7d3
Date of last revision 2024-04-15T22:11:16.649481+08:00
Data set version 00.01.005
Permanent data set URI https://lcadata.tiangong.world/showProcess.xhtml?uuid=e016e98c-bf0b-441f-882e-aa08eed3e7d3&version=01.00.000&stock=TianGong
Owner of data set
Copyright No
License type Free of charge for all users and uses

Inputs

Type of flow Classification Flow Location Mean amount Resulting amount Minimum amount Maximum amount
Product flow
Systems / Paints and chemical preparations 1000.0 kg1000.0 kg
General comment nan

Outputs

Type of flow Classification Flow Location Mean amount Resulting amount Minimum amount Maximum amount
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 24.0 kg24.0 kg
General comment the treatment technology for the pollution of volatile organic compounddidn't offered,Its Technical efficiency of end-of-pipe management94,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 40.0 kg40.0 kg
General comment the treatment technology for the pollution of volatile organic compounddidn't offered,Its Technical efficiency of end-of-pipe management90,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 60.0 kg60.0 kg
General comment the treatment technology for the pollution of volatile organic compounddidn't offered,Its Technical efficiency of end-of-pipe management85
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 60.0 kg60.0 kg
General comment the treatment technology for the pollution of volatile organic compounddidn't offered,Its Technical efficiency of end-of-pipe management85,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 140.0 kg140.0 kg
General comment the treatment technology for the pollution of volatile organic compounddidn't offered,Its Technical efficiency of end-of-pipe management65,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 188.0 kg188.0 kg
General comment the treatment technology for the pollution of volatile organic compounddidn't offered,Its Technical efficiency of end-of-pipe management53,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 244.0 kg244.0 kg
General comment the treatment technology for the pollution of volatile organic compounddidn't offered,Its Technical efficiency of end-of-pipe management39,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 264.0 kg264.0 kg
General comment the treatment technology for the pollution of volatile organic compounddidn't offered,Its Technical efficiency of end-of-pipe management34
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 332.0 kg332.0 kg
General comment the treatment technology for the pollution of volatile organic compounddidn't offered,Its Technical efficiency of end-of-pipe management17
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 332.0 kg332.0 kg
General comment the treatment technology for the pollution of volatile organic compounddidn't offered,Its Technical efficiency of end-of-pipe management17,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 340.0 kg340.0 kg
General comment the treatment technology for the pollution of volatile organic compounddidn't offered,Its Technical efficiency of end-of-pipe management15,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 352.0 kg352.0 kg
General comment the treatment technology for the pollution of volatile organic compounddidn't offered,Its Technical efficiency of end-of-pipe management12
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 400.0 kg400.0 kg
General comment the treatment technology for the pollution of volatile organic compounddidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /