Use advice for data set This dataset is derived from the Pollution Source Census Report and contains information on pollution emissions and related products. However, it does not include data on energy or chemical consumption, nor does it provide information on waste or co-product generation. When utilizing this dataset, please supplement the missing data based on actual conditions before use
Technical purpose of product or process 所述的溶剂型胶粘剂用于木门窗、木楼梯、实木复合地板以及强化木地板和其他木制品(木制容器、软木制品)的粘接工艺,采用涂胶、淋胶或喷胶的方法,并适用于各种规模的生产设施。在这些工艺中,用于控制挥发性有机化合物(VOCs)排放的末端处理技术包括活性炭纤维或沸石吸附/解吸与催化氧化,活性炭吸附/解吸催化燃烧,蒸汽解吸,低温等离子,光解,以及在某些情况下直接排放不进行处理。
Classification
Class name : Hierarchy level
  • ILCD: Reference Parameters / Materials production / Organic chemicals
General comment on data set the treatment technology for the pollution of Exhaust gasdidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = operating time of wastewater treatment facilities (hours) / normal production time (hours)
Copyright No
Owner of data set
Quantitative reference
Reference flow(s)
Technological representativeness
Technology description including background system the treatment technology for the pollution of Exhaust gasdidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = operating time of wastewater treatment facilities (hours) / normal production time (hours)
LCI method and allocation
Type of data set Unit process, single operation
Data sources, treatment and representativeness
Deviation from data treatment and extrapolations principles / explanations None
Data source(s) used for this data set
Completeness
Completeness of product model No statement
Validation
Type of review
Dependent internal review
Reviewer name and institution
Data generator
Data set generator / modeller
Publication and ownership
UUID ff6be9ef-6441-4e3c-8c02-97c591cb0006
Date of last revision 2024-04-15T22:12:29.145518+08:00
Data set version 00.01.005
Permanent data set URI https://lcadata.tiangong.world/showProcess.xhtml?uuid=ff6be9ef-6441-4e3c-8c02-97c591cb0006&version=01.00.000&stock=TianGong
Owner of data set
Copyright No
License type Free of charge for all users and uses

Inputs

Outputs

Type of flow Classification Flow Location Mean amount Resulting amount Minimum amount Maximum amount
Product flow
Systems / Construction 1.0 m31.0 m3
General comment nan
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.003375 kg0.003375 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisOthers (activated carbon fiber or zeolite adsorption/desorption/catalytic oxidation),Its Technical efficiency of end-of-pipe management85,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = operating time of wastewater treatment facilities (hours) / normal production time (hours)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.0045000000000000005 kg0.0045000000000000005 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisActivated carbon adsorption/desorption catalytic combustion method,Its Technical efficiency of end-of-pipe management80,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = operating time of wastewater treatment facilities (hours) / normal production time (hours)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.01125 kg0.01125 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisAdsorption + steam desorption,Its Technical efficiency of end-of-pipe management50,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = operating time of wastewater treatment facilities (hours) / normal production time (hours)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.01575 kg0.01575 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisLow temperature plasma,Its Technical efficiency of end-of-pipe management30,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = operating time of wastewater treatment facilities (hours) / normal production time (hours)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.018000000000000002 kg0.018000000000000002 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisPhotolysis,Its Technical efficiency of end-of-pipe management20,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = operating time of wastewater treatment facilities (hours) / normal production time (hours)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.02115 kg0.02115 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisOthers (disposable activated carbon adsorption),Its Technical efficiency of end-of-pipe management6,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = operating time of wastewater treatment facilities (hours) / normal production time (hours)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.0225 kg0.0225 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisDirect discharge,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = operating time of wastewater treatment facilities (hours) / normal production time (hours)
Product flow
Materials production / Inorganic chemicals 245.0 m3245.0 m3
General comment the treatment technology for the pollution of Exhaust gasdidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = operating time of wastewater treatment facilities (hours) / normal production time (hours)