Close Go back Collapse all sections
Process Data set: Waste and scrap refrigerator ; Steel scrap, plastic scrap, glass scrap, circuit board scrap ; Refrigerant extraction + disassembly + crushing ; All sizes; NESPS2 (en) en zh

Key Data Set Information
Location CN
Reference year 2019
Name
Waste and scrap refrigerator ; Steel scrap, plastic scrap, glass scrap, circuit board scrap ; Refrigerant extraction + disassembly + crushing ; All sizes; NESPS2
Use advice for data set This dataset is derived from the Pollution Source Census Report and contains information on pollution emissions and related products. However, it does not include data on energy or chemical consumption, nor does it provide information on waste or co-product generation. When utilizing this dataset, please supplement the missing data based on actual conditions before use
Technical purpose of product or process 所述工业过程涉及废旧电器的回收,特别是冰箱。它包括提取冷媒,以及废弃单位中的钢铁废料、塑料废料、玻璃废料和线路板废料的拆解和粉碎步骤。用于控制颗粒物(PM2.5 - PM10)的末端管理技术包括效率为95%的袋式过滤器,以及与99%效率的旋风除尘和袋式过滤器相结合的技术。该过程适用于管理各种规模的电子废物(e-waste)的废物处理和回收设施,旨在减少环境影响并回收有价值的材料。
Classification
Class name : Hierarchy level
  • ILCD: Reference Parameters / End-of-life treatment / Material recycling
General comment on data set the Technical of end-of-pipe management technology for pollution Exhaust gasis/,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
Copyright No
Owner of data set
Quantitative reference
Reference flow(s)
Technological representativeness
Technology description including background system the Technical of end-of-pipe management technology for pollution Exhaust gasis/,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
LCI method and allocation
Type of data set Unit process, single operation
Data sources, treatment and representativeness
Deviation from data treatment and extrapolations principles / explanations None
Data source(s) used for this data set
Completeness
Completeness of product model No statement
Validation
Type of review
Dependent internal review
Reviewer name and institution
Data generator
Data set generator / modeller
Publication and ownership
UUID 02f80e4a-03c4-4d89-b3f2-2bb0a20d09a5
Date of last revision 2024-04-15T22:03:06.330179+08:00
Data set version 00.01.005
Permanent data set URI https://lcadata.tiangong.world/showProcess.xhtml?uuid=02f80e4a-03c4-4d89-b3f2-2bb0a20d09a5&version=01.00.000&stock=TianGong
Owner of data set
Copyright No
License type Free of charge for all users and uses

Inputs

Type of flow Classification Flow Location Mean amount Resulting amount Minimum amount Maximum amount
Product flow
Materials production / Metals and semimetals 1000.0 kg1000.0 kg
General comment nan

Outputs

Type of flow Classification Flow Location Mean amount Resulting amount Minimum amount Maximum amount
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.01112 kg0.01112 kg
General comment the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isCyclone dust removal + bag filter,Its Technical efficiency of end-of-pipe management99,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.055600000000000004 kg0.055600000000000004 kg
General comment the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isBag filter,Its Technical efficiency of end-of-pipe management95,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Product flow
Materials production / Inorganic chemicals 7460.0 m37460.0 m3
General comment the Technical of end-of-pipe management technology for pollution Exhaust gasis/,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)