Close Go back Collapse all sections
Process Data set: Polyurethane synthetic leather ; Polyurethane paste, base cloth, dimethylformamide (DMF), surface treatment agent ; Wet process + dry process + post-treatment ; All sizes; NESPS2 (en) en zh

Key Data Set Information
Location CN
Reference year 2019
Name
Polyurethane synthetic leather ; Polyurethane paste, base cloth, dimethylformamide (DMF), surface treatment agent ; Wet process + dry process + post-treatment ; All sizes; NESPS2
Use advice for data set This dataset is derived from the Pollution Source Census Report and contains information on pollution emissions and related products. However, it does not include data on energy or chemical consumption, nor does it provide information on waste or co-product generation. When utilizing this dataset, please supplement the missing data based on actual conditions before use
Technical purpose of product or process 该数据集涉及聚氨酯合成革的生产,包括聚氨酯浆料,基布和二甲基甲酰胺(DMF)等原材料,并通过适合所有生产规模的湿法,干法和后处理表面处理工艺。它通常用作制造各种消费品的材料,包括时尚配饰,家具装饰和汽车内饰。所述的管道末端污染管理技术用于控制和减少排放气体和挥发性有机化合物(VOCs),以及处理废水和管理废水中的化学需氧量,氨氮,总磷和有机氮。
Classification
Class name : Hierarchy level
  • ILCD: Reference Parameters / Materials production / Plastics
General comment on data set the Technical of end-of-pipe management technology for pollution Exhaust gasis/,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = operating time of wastewater treatment facilities (hours/year) / normal production time (hours/year)
Copyright No
Owner of data set
Quantitative reference
Reference flow(s)
Technological representativeness
Technology description including background system the Technical of end-of-pipe management technology for pollution Exhaust gasis/,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = operating time of wastewater treatment facilities (hours/year) / normal production time (hours/year)
LCI method and allocation
Type of data set Unit process, single operation
Data sources, treatment and representativeness
Deviation from data treatment and extrapolations principles / explanations None
Data source(s) used for this data set
Completeness
Completeness of product model No statement
Validation
Type of review
Dependent internal review
Reviewer name and institution
Data generator
Data set generator / modeller
Publication and ownership
UUID 131a20d5-bb91-4c47-9992-994b28e1bd7c
Date of last revision 2024-04-15T22:03:34.898777+08:00
Data set version 00.01.005
Permanent data set URI https://lcadata.tiangong.world/showProcess.xhtml?uuid=131a20d5-bb91-4c47-9992-994b28e1bd7c&version=01.00.000&stock=TianGong
Owner of data set
Copyright No
License type Free of charge for all users and uses

Inputs

Outputs

Type of flow Classification Flow Location Mean amount Resulting amount Minimum amount Maximum amount
Product flow
Materials production / Plastics 10000.0 m210000.0 m2
General comment nan
Product flow
Materials production / Plastics 1.0 m21.0 m2
General comment nan
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 4.2 kg4.2 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisRegenerative thermal combustion method,Its Technical efficiency of end-of-pipe management95,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.008 kg0.008 kg
General comment the Technical of end-of-pipe management technology for pollution phosphorus, totalisAnaerobic biological treatment + aerobic biological treatment + physicochemical treatment,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.008 kg0.008 kg
General comment the Technical of end-of-pipe management technology for pollution phosphorus, totalisAnaerobic biological treatment + aerobic biological treatment,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 16.8 kg16.8 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisLow temperature plasma + activated carbon adsorption,Its Technical efficiency of end-of-pipe management80,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 16.8 kg16.8 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisPhotocatalysis + activated carbon adsorption,Its Technical efficiency of end-of-pipe management80,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = operating time of wastewater treatment facilities (hours/year) / normal production time (hours/year)
20000.0 20000.0
General comment the Technical of end-of-pipe management technology for pollution Waste wateris/,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 25.2 kg25.2 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisActivated carbon adsorption,Its Technical efficiency of end-of-pipe management70,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = operating time of wastewater treatment facilities (hours/year) / normal production time (hours/year)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 25.2 kg25.2 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisPhotocatalysis + low temperature plasma,Its Technical efficiency of end-of-pipe management70,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 37.8 kg37.8 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisLow temperature plasma,Its Technical efficiency of end-of-pipe management55,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 50.4 kg50.4 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisPhotocatalysis,Its Technical efficiency of end-of-pipe management40,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 50.4 kg50.4 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisPhotolysis,Its Technical efficiency of end-of-pipe management40,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
0.065 0.065
General comment the Technical of end-of-pipe management technology for pollution Ammonia NitrogenisAnaerobic biological treatment + aerobic biological treatment + physicochemical treatment,Its Technical efficiency of end-of-pipe management95,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 84.0 kg84.0 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisOthers (direct discharge),Its Technical efficiency of end-of-pipe management0,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = operating time of wastewater treatment facilities (hours/year) / normal production time (hours/year)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.4104 kg0.4104 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen, organic boundisAnaerobic biological treatment + aerobic biological treatment + physicochemical treatment,Its Technical efficiency of end-of-pipe management92,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = operating time of wastewater treatment facilities (hours/year) / normal production time (hours/year)
0.52 0.52
General comment the Technical of end-of-pipe management technology for pollution Ammonia NitrogenisAnaerobic biological treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management60,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 1.62 kg1.62 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisAnaerobic biological treatment + aerobic biological treatment + physicochemical treatment,Its Technical efficiency of end-of-pipe management94,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 1.62 kg1.62 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisAnaerobic biological treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management94,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = operating time of wastewater treatment facilities (hours/year) / normal production time (hours/year)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 3.078 kg3.078 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen, organic boundisAnaerobic biological treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management40,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Product flow
Materials production / Inorganic chemicals 781000.0 m3781000.0 m3
General comment the Technical of end-of-pipe management technology for pollution Exhaust gasis/,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = operating time of wastewater treatment facilities (hours/year) / normal production time (hours/year)