Close Go back Collapse all sections
Process Data set: Veterinary chemical preparations ; Chemical Pharmaceutical Ingredients ; Liquid preparation ; 500~5000 t/a; NESPS2 (en) en zh

Key Data Set Information
Location CN
Reference year 2019
Name
Veterinary chemical preparations ; Chemical Pharmaceutical Ingredients ; Liquid preparation ; 500~5000 t/a; NESPS2
Use advice for data set This dataset is derived from the Pollution Source Census Report and contains information on pollution emissions and related products. However, it does not include data on energy or chemical consumption, nor does it provide information on waste or co-product generation. When utilizing this dataset, please supplement the missing data based on actual conditions before use
Technical purpose of product or process 该工艺用于生产兽用化学药品、化学药品原料药和液体制剂,产量范围为每年500至5000吨。它揭示了在将废水和废气排放到环境之前,采用末端控制技术处理多种污染物,包括化学需氧量(COD)、氨氮、总磷、有机结合氮和挥发性有机化合物(VOCs)。
Classification
Class name : Hierarchy level
  • ILCD: Reference Parameters / Materials production / Organic chemicals
General comment on data set the Technical of end-of-pipe management technology for pollution Exhaust gasis/,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is K = normal operation time of wastewater treatment facility (hours/year) / normal production time of enterprises (hours/year)
Copyright No
Owner of data set
Quantitative reference
Reference flow(s)
Technological representativeness
Technology description including background system the Technical of end-of-pipe management technology for pollution Exhaust gasis/,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is K = normal operation time of wastewater treatment facility (hours/year) / normal production time of enterprises (hours/year)
LCI method and allocation
Type of data set Unit process, single operation
Data sources, treatment and representativeness
Deviation from data treatment and extrapolations principles / explanations None
Data source(s) used for this data set
Completeness
Completeness of product model No statement
Validation
Type of review
Dependent internal review
Reviewer name and institution
Data generator
Data set generator / modeller
Publication and ownership
UUID 1759d862-26a0-4558-a05c-9489280df860
Date of last revision 2024-04-15T22:03:39.941178+08:00
Data set version 00.01.005
Permanent data set URI https://lcadata.tiangong.world/showProcess.xhtml?uuid=1759d862-26a0-4558-a05c-9489280df860&version=01.00.000&stock=TianGong
Owner of data set
Copyright No
License type Free of charge for all users and uses

Inputs

Outputs

Type of flow Classification Flow Location Mean amount Resulting amount Minimum amount Maximum amount
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 4.800000000000012E-5 kg4.800000000000012E-5 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisAdsorption + steam desorption,Its Technical efficiency of end-of-pipe management98.8,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is K = normal operation time of wastewater treatment facility (hours/year) / normal production time of enterprises (hours/year)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 4.0E-4 kg4.0E-4 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisAbsorption + diversion,Its Technical efficiency of end-of-pipe management90,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is K = normal operation time of wastewater treatment facility (hours/year) / normal production time of enterprises (hours/year)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.0028 kg0.0028 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisLow temperature plasma,Its Technical efficiency of end-of-pipe management30,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is K = normal operation time of wastewater treatment facility (hours/year) / normal production time of enterprises (hours/year)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.004 kg0.004 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisWithout terminal treatment facility,Its Technical efficiency of end-of-pipe management0,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is K = normal operation time of wastewater treatment facility (hours/year) / normal production time of enterprises (hours/year)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.02474400000000005 kg0.02474400000000005 kg
General comment the Technical of end-of-pipe management technology for pollution phosphorus, totalisPhysicochemical treatment + anaerobic/aerobic biological combined treatment + physicochemical treatment,Its Technical efficiency of end-of-pipe management98.8,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is K = normal operation time of wastewater treatment facility (hours/year) / normal production time of enterprises (hours/year)
0.148335 0.148335
General comment the Technical of end-of-pipe management technology for pollution Ammonia NitrogenisPhysicochemical treatment + anaerobic/aerobic biological combined treatment + physicochemical treatment,Its Technical efficiency of end-of-pipe management94.5,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is K = normal operation time of wastewater treatment facility (hours/year) / normal production time of enterprises (hours/year)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.17527 kg0.17527 kg
General comment the Technical of end-of-pipe management technology for pollution phosphorus, totalisPhysicochemical treatment + anaerobic biological treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management91.5,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is K = normal operation time of wastewater treatment facility (hours/year) / normal production time of enterprises (hours/year)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.238735 kg0.238735 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen, organic boundisPhysicochemical treatment + anaerobic/aerobic biological combined treatment + physicochemical treatment,Its Technical efficiency of end-of-pipe management96.5,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is K = normal operation time of wastewater treatment facility (hours/year) / normal production time of enterprises (hours/year)
0.2400330000000002 0.2400330000000002
General comment the Technical of end-of-pipe management technology for pollution Ammonia NitrogenisPhysicochemical treatment + anaerobic biological treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management91.1,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is K = normal operation time of wastewater treatment facility (hours/year) / normal production time of enterprises (hours/year)
0.250821 0.250821
General comment the Technical of end-of-pipe management technology for pollution Ammonia NitrogenisPhysicochemical treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management90.7,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is K = normal operation time of wastewater treatment facility (hours/year) / normal production time of enterprises (hours/year)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.27837 kg0.27837 kg
General comment the Technical of end-of-pipe management technology for pollution phosphorus, totalisPhysicochemical treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management86.5,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = opreating time of treatment facilities (hours/year) / normal production time (hours/year)
Product flow
Materials production / Other materials 1000.0 kg1000.0 kg
General comment nan
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 1.459694 kg1.459694 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen, organic boundisPhysicochemical treatment + anaerobic biological treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management78.6,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is K = normal operation time of wastewater treatment facility (hours/year) / normal production time of enterprises (hours/year)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 1.560910999999998 kg1.560910999999998 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisPhysicochemical treatment + anaerobic/aerobic biological combined treatment + physicochemical treatment,Its Technical efficiency of end-of-pipe management95.9,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is K = normal operation time of wastewater treatment facility (hours/year) / normal production time of enterprises (hours/year)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 2.039479 kg2.039479 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen, organic boundisPhysicochemical treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management70.1,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is K = normal operation time of wastewater treatment facility (hours/year) / normal production time of enterprises (hours/year)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 2.062 kg2.062 kg
General comment the Technical of end-of-pipe management technology for pollution phosphorus, totalisWithout terminal treatment facility,Its Technical efficiency of end-of-pipe management0,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is K = normal operation time of wastewater treatment facility (hours/year) / normal production time of enterprises (hours/year)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 2.626899000000002 kg2.626899000000002 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisPhysicochemical treatment + anaerobic biological treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management93.1,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is K = normal operation time of wastewater treatment facility (hours/year) / normal production time of enterprises (hours/year)
2.697 2.697
General comment the Technical of end-of-pipe management technology for pollution Ammonia NitrogenisWithout terminal treatment facility,Its Technical efficiency of end-of-pipe management0,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is K = normal operation time of wastewater treatment facility (hours/year) / normal production time of enterprises (hours/year)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 3.654815999999998 kg3.654815999999998 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisPhysicochemical treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management90.4,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is K = normal operation time of wastewater treatment facility (hours/year) / normal production time of enterprises (hours/year)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 6.821000000000001 kg6.821000000000001 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen, organic boundisWithout terminal treatment facility,Its Technical efficiency of end-of-pipe management0,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is K = normal operation time of wastewater treatment facility (hours/year) / normal production time of enterprises (hours/year)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 38.071 kg38.071 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisWithout terminal treatment facility,Its Technical efficiency of end-of-pipe management0,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is K = normal operation time of wastewater treatment facility (hours/year) / normal production time of enterprises (hours/year)
158.63 158.63
General comment the Technical of end-of-pipe management technology for pollution Waste wateris/,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is K = normal operation time of wastewater treatment facility (hours/year) / normal production time of enterprises (hours/year)
Product flow
Materials production / Inorganic chemicals 159.21 m3159.21 m3
General comment the Technical of end-of-pipe management technology for pollution Exhaust gasis/,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is K = normal operation time of wastewater treatment facility (hours/year) / normal production time of enterprises (hours/year)