Close Go back Collapse all sections
Process Data set: Sheepskin/fine-mixed skins-finished fur (chrome tanned) ; Finished fur ; Sheepskin/fine mixed skin ; Chrome main tanning ; All sizes; NESPS2 (en) en zh

Key Data Set Information
Location CN
Reference year 2019
Name
Sheepskin/fine-mixed skins-finished fur (chrome tanned) ; Finished fur ; Sheepskin/fine mixed skin ; Chrome main tanning ; All sizes; NESPS2
Use advice for data set This dataset is derived from the Pollution Source Census Report and contains information on pollution emissions and related products. However, it does not include data on energy or chemical consumption, nor does it provide information on waste or co-product generation. When utilizing this dataset, please supplement the missing data based on actual conditions before use
Technical purpose of product or process 所描述的工业过程涉及使用铬鞣法对羊皮和细杂皮进行鞣制,制成成品毛皮。这种成品毛皮适用于时尚和服装行业,用于生产皮革制品、服装和配饰。所提供的末端管控技术与污染控制有关,用于处理铬鞣工艺的副产品,包括磷、总铬、氨态氮、有机结合氮、化学需氧量、挥发性有机化合物和废水及排气排放中的颗粒物。这些技术适用于对这些特定污染物表示关注并需要先进处理方法的行业,以符合环保法规。
Classification
Class name : Hierarchy level
  • ILCD: Reference Parameters / Materials production / Other materials
General comment on data set the treatment technology for the pollution of Waste waterdidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Copyright No
Owner of data set
Quantitative reference
Reference flow(s)
Technological representativeness
Technology description including background system the treatment technology for the pollution of Waste waterdidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
LCI method and allocation
Type of data set Unit process, single operation
Data sources, treatment and representativeness
Deviation from data treatment and extrapolations principles / explanations None
Data source(s) used for this data set
Completeness
Completeness of product model No statement
Validation
Type of review
Dependent internal review
Reviewer name and institution
Data generator
Data set generator / modeller
Publication and ownership
UUID 1e8f6a1d-e53b-4bbb-9b06-3c9f59b297f9
Date of last revision 2024-04-15T22:03:52.051202+08:00
Data set version 00.01.005
Permanent data set URI https://lcadata.tiangong.world/showProcess.xhtml?uuid=1e8f6a1d-e53b-4bbb-9b06-3c9f59b297f9&version=01.00.000&stock=TianGong
Owner of data set
Copyright No
License type Free of charge for all users and uses

Inputs

Type of flow Classification Flow Location Mean amount Resulting amount Minimum amount Maximum amount
Product flow
Materials production / Other materials 1.0 Item(s)1.0 Item(s)
General comment nan

Outputs

Type of flow Classification Flow Location Mean amount Resulting amount Minimum amount Maximum amount
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.425 kg0.425 kg
General comment the Technical of end-of-pipe management technology for pollution phosphorus, totalisPhysicochemical treatment + aerobic biological treatment + physical treatment,Its Technical efficiency of end-of-pipe management99,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.455 kg0.455 kg
General comment the Technical of end-of-pipe management technology for pollution ChromiumisPhysicochemical treatment + aerobic biological treatment + chemical treatment,Its Technical efficiency of end-of-pipe management99,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.455 kg0.455 kg
General comment the Technical of end-of-pipe management technology for pollution ChromiumisPhysicochemical treatment + aerobic biological treatment + physical treatment,Its Technical efficiency of end-of-pipe management99,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.455 kg0.455 kg
General comment the Technical of end-of-pipe management technology for pollution ChromiumisPhysicochemical treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management99,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.8500000000000001 kg0.8500000000000001 kg
General comment the Technical of end-of-pipe management technology for pollution phosphorus, totalisPhysicochemical treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management98,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 4.675000000000001 kg4.675000000000001 kg
General comment the Technical of end-of-pipe management technology for pollution phosphorus, totalisPhysicochemical treatment + aerobic biological treatment + chemical treatment,Its Technical efficiency of end-of-pipe management89,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
5.94 5.94
General comment the Technical of end-of-pipe management technology for pollution Ammonia NitrogenisPhysicochemical treatment + aerobic biological treatment + physical treatment,Its Technical efficiency of end-of-pipe management96,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
8.91 8.91
General comment the Technical of end-of-pipe management technology for pollution Ammonia NitrogenisPhysicochemical treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management94,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 9.375 kg9.375 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen, organic boundisPhysicochemical treatment + aerobic biological treatment + chemical treatment,Its Technical efficiency of end-of-pipe management95,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
10.395 10.395
General comment the Technical of end-of-pipe management technology for pollution Ammonia NitrogenisPhysicochemical treatment + aerobic biological treatment + chemical treatment,Its Technical efficiency of end-of-pipe management93,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 20.625 kg20.625 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen, organic boundisPhysicochemical treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management89,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 24.375 kg24.375 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen, organic boundisPhysicochemical treatment + aerobic biological treatment + physical treatment,Its Technical efficiency of end-of-pipe management87,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 37.835 kg37.835 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisPhysicochemical treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management99,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.15 kg0.15 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisV19 Others (adsorption method),Its Technical efficiency of end-of-pipe management85
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.22 kg0.22 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisV19 Others (spray tower),Its Technical efficiency of end-of-pipe management78
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 227.01 kg227.01 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisPhysicochemical treatment + aerobic biological treatment + chemical treatment,Its Technical efficiency of end-of-pipe management94,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 227.01 kg227.01 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisPhysicochemical treatment + aerobic biological treatment + physical treatment,Its Technical efficiency of end-of-pipe management94,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.27 kg0.27 kg
General comment the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isBag filter,Its Technical efficiency of end-of-pipe management94,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.3 kg0.3 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisPhotocatalysis,Its Technical efficiency of end-of-pipe management70,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Product flow
Materials production / Inorganic chemicals 393200.0 m3393200.0 m3
General comment the treatment technology for the pollution of Exhaust gasdidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
1769.5 1769.5
General comment the treatment technology for the pollution of Waste waterdidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /