Close Go back Collapse all sections
Process Data set: Cigarette manufacturing ; Cigarette Rolling ; Bituminous leaves, tobacco stalks, aromatic sugar materials, flakes ; Filament, coiling package, molding process ; greater than or equal to1 million cases/a; NESPS2 (en) en zh

Key Data Set Information
Location CN
Reference year 2019
Name
Cigarette manufacturing ; Cigarette Rolling ; Bituminous leaves, tobacco stalks, aromatic sugar materials, flakes ; Filament, coiling package, molding process ; greater than or equal to1 million cases/a; NESPS2
Use advice for data set This dataset is derived from the Pollution Source Census Report and contains information on pollution emissions and related products. However, it does not include data on energy or chemical consumption, nor does it provide information on waste or co-product generation. When utilizing this dataset, please supplement the missing data based on actual conditions before use
Technical purpose of product or process 该数据集描述了大规模烟草制造的生产过程,特别是年产量大于或等于100万箱的操作。该过程包括处理诸如沥青叶、烟梗、香糖料和薄片等材料,并涉及丝束制造、卷接包装和成型工艺。此数据与评估香烟的工业生产及相应采取的污染控制措施有关,包括使用MBR(膜生物反应器)、A/O(缺氧/好氧)工艺、生物接触氧化工艺处理氨氮和化学需氧量(COD)污染,以及袋式滤器和旋风除尘+袋式滤器技术来管理颗粒物(PM2.5 - PM10)。
Classification
Class name : Hierarchy level
  • ILCD: Reference Parameters / Materials production / Organic chemicals
General comment on data set the treatment technology for the pollution of Exhaust gasdidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = actual operating hours of environmental protection facilities (hours) / hours that environmental protection facilities should operate (hours)
Copyright No
Owner of data set
Quantitative reference
Reference flow(s)
  • - 10000.0 * 1.0 Item(s) (Number of items)
Technological representativeness
Technology description including background system the treatment technology for the pollution of Exhaust gasdidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = actual operating hours of environmental protection facilities (hours) / hours that environmental protection facilities should operate (hours)
LCI method and allocation
Type of data set Unit process, single operation
Data sources, treatment and representativeness
Deviation from data treatment and extrapolations principles / explanations None
Data source(s) used for this data set
Completeness
Completeness of product model No statement
Validation
Type of review
Dependent internal review
Reviewer name and institution
Data generator
Data set generator / modeller
Publication and ownership
UUID 21a761fe-e037-4897-8451-861e5bd9cec0
Date of last revision 2024-04-15T22:03:59.126383+08:00
Data set version 00.01.005
Permanent data set URI https://lcadata.tiangong.world/showProcess.xhtml?uuid=21a761fe-e037-4897-8451-861e5bd9cec0&version=01.00.000&stock=TianGong
Owner of data set
Copyright No
License type Free of charge for all users and uses

Inputs

Outputs

Type of flow Classification Flow Location Mean amount Resulting amount Minimum amount Maximum amount
4.001800000000001E-5 4.001800000000001E-5
General comment the Technical of end-of-pipe management technology for pollution Ammonia NitrogenisMBR,Its Technical efficiency of end-of-pipe management89.3,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = actual operating hours of environmental protection facilities (hours) / hours that environmental protection facilities should operate (hours)
4.5628E-5 4.5628E-5
General comment the Technical of end-of-pipe management technology for pollution Ammonia NitrogenisA/O process,Its Technical efficiency of end-of-pipe management87.8,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = actual operating hours of environmental protection facilities (hours) / hours that environmental protection facilities should operate (hours)
4.5628E-5 4.5628E-5
General comment the Technical of end-of-pipe management technology for pollution Ammonia NitrogenisBio-contact oxidation process,Its Technical efficiency of end-of-pipe management87.8,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = actual operating hours of environmental protection facilities (hours) / hours that environmental protection facilities should operate (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 9.99600000000001E-4 kg9.99600000000001E-4 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisMBR,Its Technical efficiency of end-of-pipe management95.1,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = actual operating hours of environmental protection facilities (hours) / hours that environmental protection facilities should operate (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.003753600000000001 kg0.003753600000000001 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisA/O process,Its Technical efficiency of end-of-pipe management81.6
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.003753600000000001 kg0.003753600000000001 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisBio-contact oxidation process,Its Technical efficiency of end-of-pipe management81.6
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.005775 kg0.005775 kg
General comment the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isBag filter,Its Technical efficiency of end-of-pipe management98.5,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = actual operating hours of environmental protection facilities (hours) / hours that environmental protection facilities should operate (hours)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.005775 kg0.005775 kg
General comment the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isCyclone dust removal + bag filter,Its Technical efficiency of end-of-pipe management98.5,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = actual operating hours of environmental protection facilities (hours) / hours that environmental protection facilities should operate (hours)
43.3 43.3
General comment the treatment technology for the pollution of Waste waterdidn't offered
Product flow
Materials production / Organic chemicals 10000.0 Item(s)10000.0 Item(s)
General comment nan
Product flow
Materials production / Inorganic chemicals 225.0 m3225.0 m3
General comment the treatment technology for the pollution of Exhaust gasdidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = actual operating hours of environmental protection facilities (hours) / hours that environmental protection facilities should operate (hours)