Process Data set: Genetically engineered drugs and vaccines ; Microorganisms and microbial metabolites or animal serum ; Bioengineering process ; greater than or equal to10000 kg/a; NESPS2 (en) en zh

Key Data Set Information
Location CN
Reference year 2019
Name
Genetically engineered drugs and vaccines ; Microorganisms and microbial metabolites or animal serum ; Bioengineering process ; greater than or equal to10000 kg/a; NESPS2
Use advice for data set This dataset is derived from the Pollution Source Census Report and contains information on pollution emissions and related products. However, it does not include data on energy or chemical consumption, nor does it provide information on waste or co-product generation. When utilizing this dataset, please supplement the missing data based on actual conditions before use
Technical purpose of product or process 此技术应用涉及年产量大于或等于10000千克的基因工程药物和疫苗、微生物及其代谢产物或动物血清的生物工程工艺。 该工业过程产生的废水通过各种尾端处理技术进行管理,包括物理化学处理、好氧和缺氧生物处理以及厌氧水解。 这些技术的效率根据它们的组合和正在处理的特定污染物而变化,根据化学需氧量 (COD)、氨氮、有机结合氮、总磷和挥发性有机化合物 (VOCs) 来衡量。
Classification
Class name : Hierarchy level
  • ILCD: Reference Parameters / Other Services / Research and development
General comment on data set the Technical of end-of-pipe management technology for pollution Waste wateris/,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual operating time of wastewater treatment facilities (hours) / annual normal production time of enterprises (hours)
Copyright No
Owner of data set
Quantitative reference
Reference flow(s)
Technological representativeness
Technology description including background system the Technical of end-of-pipe management technology for pollution Waste wateris/,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual operating time of wastewater treatment facilities (hours) / annual normal production time of enterprises (hours)
LCI method and allocation
Type of data set Unit process, single operation
Data sources, treatment and representativeness
Deviation from data treatment and extrapolations principles / explanations None
Data source(s) used for this data set
Completeness
Completeness of product model No statement
Validation
Type of review
Dependent internal review
Reviewer name and institution
Data generator
Data set generator / modeller
Publication and ownership
UUID 246f8e11-d8e7-4fc7-b108-27ad6f0a61ba
Date of last revision 2024-04-15T22:04:12.993895+08:00
Data set version 00.01.005
Permanent data set URI https://lcadata.tiangong.world/showProcess.xhtml?uuid=246f8e11-d8e7-4fc7-b108-27ad6f0a61ba&version=01.00.000&stock=TianGong
Owner of data set
Copyright No
License type Free of charge for all users and uses

Inputs

Outputs

Type of flow Classification Flow Location Mean amount Resulting amount Minimum amount Maximum amount
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 6.0E-5 kg6.0E-5 kg
General comment the Technical of end-of-pipe management technology for pollution phosphorus, totalisPhysicochemical treatment + anaerobic biological treatment + anoxic/aerobic biological treatment,Its Technical efficiency of end-of-pipe management99,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual operating time of wastewater treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 9.0E-5 kg9.0E-5 kg
General comment the Technical of end-of-pipe management technology for pollution phosphorus, totalisPhysicochemical treatment + anoxic/aerobic biological treatment,Its Technical efficiency of end-of-pipe management98.5,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual operating time of wastewater treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 1.379999999999998E-4 kg1.379999999999998E-4 kg
General comment the Technical of end-of-pipe management technology for pollution phosphorus, totalisPhysicochemical treatment + anaerobic hydrolysis + aerobic biological treatment,Its Technical efficiency of end-of-pipe management97.7,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual operating time of wastewater treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 2.1E-4 kg2.1E-4 kg
General comment the Technical of end-of-pipe management technology for pollution phosphorus, totalisPhysicochemical treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management96.5,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual operating time of wastewater treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 6.0E-4 kg6.0E-4 kg
General comment the Technical of end-of-pipe management technology for pollution phosphorus, totalisOther,Its Technical efficiency of end-of-pipe management90,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual operating time of wastewater treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.00161 kg0.00161 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisRegenerative catalytic combustion method,Its Technical efficiency of end-of-pipe management99,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual operating time of waste gas treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.001932000000000004 kg0.001932000000000004 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisAdsorption + steam desorption,Its Technical efficiency of end-of-pipe management98.8,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual operating time of waste gas treatment facilities (hours) / annual normal production time of enterprises (hours)
0.00305 0.00305
General comment the Technical of end-of-pipe management technology for pollution Ammonia NitrogenisPhysicochemical treatment + anoxic/aerobic biological treatment,Its Technical efficiency of end-of-pipe management95,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual operating time of wastewater treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.006 kg0.006 kg
General comment the Technical of end-of-pipe management technology for pollution phosphorus, totalisWithout terminal treatment technology,Its Technical efficiency of end-of-pipe management0,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual operating time of wastewater treatment facilities (hours) / annual normal production time of enterprises (hours)
0.0061 0.0061
General comment the Technical of end-of-pipe management technology for pollution Ammonia NitrogenisOther,Its Technical efficiency of end-of-pipe management90,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual operating time of wastewater treatment facilities (hours) / annual normal production time of enterprises (hours)
0.007747000000000001 0.007747000000000001
General comment the Technical of end-of-pipe management technology for pollution Ammonia NitrogenisPhysicochemical treatment + anaerobic biological treatment + anoxic/aerobic biological treatment,Its Technical efficiency of end-of-pipe management87.3,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual operating time of wastewater treatment facilities (hours) / annual normal production time of enterprises (hours)
0.011529 0.011529
General comment the Technical of end-of-pipe management technology for pollution Ammonia NitrogenisPhysicochemical treatment + anaerobic hydrolysis + aerobic biological treatment,Its Technical efficiency of end-of-pipe management81.1,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual operating time of wastewater treatment facilities (hours) / annual normal production time of enterprises (hours)
0.011895 0.011895
General comment the Technical of end-of-pipe management technology for pollution Ammonia NitrogenisPhysicochemical treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management80.5,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual operating time of wastewater treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.01344000000000003 kg0.01344000000000003 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisPhysicochemical treatment + anaerobic biological treatment + anoxic/aerobic biological treatment,Its Technical efficiency of end-of-pipe management98.8,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual operating time of wastewater treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.01365 kg0.01365 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen, organic boundisPhysicochemical treatment + anaerobic biological treatment + anoxic/aerobic biological treatment,Its Technical efficiency of end-of-pipe management85,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual operating time of wastewater treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.015197 kg0.015197 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen, organic boundisPhysicochemical treatment + anoxic/aerobic biological treatment,Its Technical efficiency of end-of-pipe management83.3,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual operating time of wastewater treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.0161 kg0.0161 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisOther,Its Technical efficiency of end-of-pipe management90,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual operating time of waste gas treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.0273 kg0.0273 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen, organic boundisOther,Its Technical efficiency of end-of-pipe management70,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual operating time of wastewater treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.032487 kg0.032487 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen, organic boundisPhysicochemical treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management64.3,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual operating time of wastewater treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.04025 kg0.04025 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisCondensation,Its Technical efficiency of end-of-pipe management75,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual operating time of waste gas treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.04277 kg0.04277 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen, organic boundisPhysicochemical treatment + anaerobic hydrolysis + aerobic biological treatment,Its Technical efficiency of end-of-pipe management53,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual operating time of wastewater treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.05488000000000007 kg0.05488000000000007 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisPhysicochemical treatment + anaerobic hydrolysis + aerobic biological treatment,Its Technical efficiency of end-of-pipe management95.1,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual operating time of wastewater treatment facilities (hours) / annual normal production time of enterprises (hours)
0.061 0.061
General comment the Technical of end-of-pipe management technology for pollution Ammonia NitrogenisWithout terminal treatment technology,Its Technical efficiency of end-of-pipe management0,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual operating time of wastewater treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.07391999999999994 kg0.07391999999999994 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisPhysicochemical treatment + anoxic/aerobic biological treatment,Its Technical efficiency of end-of-pipe management93.4,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual operating time of wastewater treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.091 kg0.091 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen, organic boundisWithout terminal treatment technology,Its Technical efficiency of end-of-pipe management0,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual operating time of wastewater treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.112 kg0.112 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisOther,Its Technical efficiency of end-of-pipe management90,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual operating time of wastewater treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.1127 kg0.1127 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisLow temperature plasma,Its Technical efficiency of end-of-pipe management30,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual operating time of waste gas treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.1355199999999999 kg0.1355199999999999 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisPhysicochemical treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management87.9,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual operating time of wastewater treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.161 kg0.161 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisWithout terminal treatment technology,Its Technical efficiency of end-of-pipe management0,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual operating time of waste gas treatment facilities (hours) / annual normal production time of enterprises (hours)
Product flow
Other Services / Research and development 1.0 kg1.0 kg
General comment nan
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 1.12 kg1.12 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisWithout terminal treatment technology,Its Technical efficiency of end-of-pipe management0,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual operating time of wastewater treatment facilities (hours) / annual normal production time of enterprises (hours)
7.18 7.18
General comment the Technical of end-of-pipe management technology for pollution Waste wateris/,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual operating time of wastewater treatment facilities (hours) / annual normal production time of enterprises (hours)