Close Go back Collapse all sections
Process Data set: Metal spraying pretreatment ; Fitness equipment ; Metal parts ; Pickling, alkali cleaning - surface treatment ; All sizes; NESPS2 (en) en zh

Key Data Set Information
Location CN
Reference year 2019
Name
Metal spraying pretreatment ; Fitness equipment ; Metal parts ; Pickling, alkali cleaning - surface treatment ; All sizes; NESPS2
Use advice for data set This dataset is derived from the Pollution Source Census Report and contains information on pollution emissions and related products. However, it does not include data on energy or chemical consumption, nor does it provide information on waste or co-product generation. When utilizing this dataset, please supplement the missing data based on actual conditions before use
Technical purpose of product or process 该数据集代表了金屏进行酸洗和碱洗表面处理的应用,特别是应用于所有规模健身器材金属件。所提供的末端处理技术的技术效率和实际运行率(k值)公式适用于处理此类工业流程废水污染的末端处理技术。这些技术包括单独的化学絮凝以及与好氧生物处理结合的化学絮凝,涉及的污染物包括化学需氧量(COD)、氨氮、总磷和有机结合氮。
Classification
Class name : Hierarchy level
  • ILCD: Reference Parameters / Systems / Other machines
General comment on data set the Technical of end-of-pipe management technology for pollution Waste wateris/,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Copyright No
Owner of data set
Quantitative reference
Reference flow(s)
  • - 1000.0 * 1.0 kg (Mass)
Technological representativeness
Technology description including background system the Technical of end-of-pipe management technology for pollution Waste wateris/,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
LCI method and allocation
Type of data set Unit process, single operation
Data sources, treatment and representativeness
Deviation from data treatment and extrapolations principles / explanations None
Data source(s) used for this data set
Completeness
Completeness of product model No statement
Validation
Type of review
Dependent internal review
Reviewer name and institution
Data generator
Data set generator / modeller
Publication and ownership
UUID 25dd7bde-2a99-4411-b0f7-6e3b620aa1cd
Date of last revision 2024-04-15T22:04:15.444123+08:00
Data set version 00.01.005
Permanent data set URI https://lcadata.tiangong.world/showProcess.xhtml?uuid=25dd7bde-2a99-4411-b0f7-6e3b620aa1cd&version=01.00.000&stock=TianGong
Owner of data set
Copyright No
License type Free of charge for all users and uses

Inputs

Type of flow Classification Flow Location Mean amount Resulting amount Minimum amount Maximum amount
Product flow
Materials production / Metals and semimetals 1000.0 kg1000.0 kg
General comment nan

Outputs

Type of flow Classification Flow Location Mean amount Resulting amount Minimum amount Maximum amount
0.0012 0.0012
General comment the Technical of end-of-pipe management technology for pollution Ammonia NitrogenisChemical coagulation + aerobic biological treatment,Its Technical efficiency of end-of-pipe management70,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual power consumption of wastewater treatment facilities (kWh) / (total rated power (kW) × annual operating time (hours))
0.002 0.002
General comment the Technical of end-of-pipe management technology for pollution Ammonia NitrogenisChemical coagulation,Its Technical efficiency of end-of-pipe management50,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual power consumption of wastewater treatment facilities (kWh) / (total rated power (kW) × annual operating time (hours))
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.008 kg0.008 kg
General comment the Technical of end-of-pipe management technology for pollution phosphorus, totalisChemical coagulation + aerobic biological treatment,Its Technical efficiency of end-of-pipe management50,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual power consumption of wastewater treatment facilities (kWh) / (total rated power (kW) × annual operating time (hours))
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.0096 kg0.0096 kg
General comment the Technical of end-of-pipe management technology for pollution phosphorus, totalisChemical coagulation,Its Technical efficiency of end-of-pipe management40,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual power consumption of wastewater treatment facilities (kWh) / (total rated power (kW) × annual operating time (hours))
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.01595 kg0.01595 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen, organic boundisChemical coagulation + aerobic biological treatment,Its Technical efficiency of end-of-pipe management45,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual power consumption of wastewater treatment facilities (kWh) / (total rated power (kW) × annual operating time (hours))
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.0174 kg0.0174 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen, organic boundisChemical coagulation,Its Technical efficiency of end-of-pipe management40,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual power consumption of wastewater treatment facilities (kWh) / (total rated power (kW) × annual operating time (hours))
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.0417 kg0.0417 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisChemical coagulation + aerobic biological treatment,Its Technical efficiency of end-of-pipe management85,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual power consumption of wastewater treatment facilities (kWh) / (total rated power (kW) × annual operating time (hours))
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.139 kg0.139 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisChemical coagulation,Its Technical efficiency of end-of-pipe management50,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual power consumption of wastewater treatment facilities (kWh) / (total rated power (kW) × annual operating time (hours))
1750.0 1750.0
General comment the Technical of end-of-pipe management technology for pollution Waste wateris/,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /