Close Go back Collapse all sections
Process Data set: Casting ; Casting ; Aluminum alloy, magnesium alloy, copper alloy, zinc alloy, aluminum ingot, copper ingot, magnesium ingot, intermediate alloy ingot, other metal materials, natural gas, gas, refining agent, denaturant ; All sizes; NESPS2 (en) en zh

Key Data Set Information
Location CN
Reference year 2019
Name
Casting ; Casting ; Aluminum alloy, magnesium alloy, copper alloy, zinc alloy, aluminum ingot, copper ingot, magnesium ingot, intermediate alloy ingot, other metal materials, natural gas, gas, refining agent, denaturant ; All sizes; NESPS2
Use advice for data set This dataset is derived from the Pollution Source Census Report and contains information on pollution emissions and related products. However, it does not include data on energy or chemical consumption, nor does it provide information on waste or co-product generation. When utilizing this dataset, please supplement the missing data based on actual conditions before use
Technical purpose of product or process 本数据集描述了各种金属材料的使用情况,包括铝合金、镁合金、铜合金以及锌合金、铝锭、铜锭和镁锭,这些都被用于所有规模的铸造过程。金属在燃气炉内熔化,使用天然气和煤气作为燃料,以及使用精炼剂和变质剂。铸造过程适用于汽车、航空航天和建筑行业等行业的组件制造。提及的末端管理技术被实施来控制这些过程中颗粒物排放(PM2.5 - PM10)。
Classification
Class name : Hierarchy level
  • ILCD: Reference Parameters / Materials production / Metals and semimetals
General comment on data set the treatment technology for the pollution of Exhaust gasdidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
Copyright No
Owner of data set
Quantitative reference
Reference flow(s)
Technological representativeness
Technology description including background system the treatment technology for the pollution of Exhaust gasdidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
LCI method and allocation
Type of data set Unit process, single operation
Data sources, treatment and representativeness
Deviation from data treatment and extrapolations principles / explanations None
Data source(s) used for this data set
Completeness
Completeness of product model No statement
Validation
Type of review
Dependent internal review
Reviewer name and institution
Data generator
Data set generator / modeller
Publication and ownership
UUID 2ca9af23-eeec-43cb-b3f4-24fda2d030ad
Date of last revision 2024-04-15T22:04:25.479528+08:00
Data set version 00.01.005
Permanent data set URI https://lcadata.tiangong.world/showProcess.xhtml?uuid=2ca9af23-eeec-43cb-b3f4-24fda2d030ad&version=01.00.000&stock=TianGong
Owner of data set
Copyright No
License type Free of charge for all users and uses

Inputs

Outputs

Type of flow Classification Flow Location Mean amount Resulting amount Minimum amount Maximum amount
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.04715 kg0.04715 kg
General comment the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isBag filter,Its Technical efficiency of end-of-pipe management95,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.04715 kg0.04715 kg
General comment the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isPlate electrostatic precipitator,Its Technical efficiency of end-of-pipe management95,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.04715 kg0.04715 kg
General comment the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isTubular filtration,Its Technical efficiency of end-of-pipe management95,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = 1
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.14145 kg0.14145 kg
General comment the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isSpray tower/water shock bath,Its Technical efficiency of end-of-pipe management85,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = 1
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.14145 kg0.14145 kg
General comment the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isVenturi,Its Technical efficiency of end-of-pipe management85,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.2829 kg0.2829 kg
General comment the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isMulti-tube cyclone dust removal,Its Technical efficiency of end-of-pipe management70,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.3772 kg0.3772 kg
General comment the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isSingle cylinder (multiple cylinders in parallel) cyclone,Its Technical efficiency of end-of-pipe management60,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.943 kg0.943 kg
General comment the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isDirect discharge,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = 1
Product flow
Materials production / Other materials 1000.0 kg1000.0 kg
General comment nan
Product flow
Materials production / Inorganic chemicals 11883.0 m311883.0 m3
General comment the treatment technology for the pollution of Exhaust gasdidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)