Close Go back Collapse all sections
Process Data set: Sintering ; Ceramic floor tile (once fired - polished) ; Feldspar, quartz, porcelain clay, etc. ; Roller kiln (water and gas) ; All sizes; NESPS2 (en) en zh

Key Data Set Information
Location CN
Reference year 2019
Name
Sintering ; Ceramic floor tile (once fired - polished) ; Feldspar, quartz, porcelain clay, etc. ; Roller kiln (water and gas) ; All sizes; NESPS2
Use advice for data set This dataset is derived from the Pollution Source Census Report and contains information on pollution emissions and related products. However, it does not include data on energy or chemical consumption, nor does it provide information on waste or co-product generation. When utilizing this dataset, please supplement the missing data based on actual conditions before use
Technical purpose of product or process 所描述的工艺包括使用长石、石英和瓷土等原料在水煤气动力的辊道窑中烧成陶瓷地砖。此工艺适用于生产各种尺寸的抛光陶瓷地砖。数据还详细介绍了各种尾气治理技术,包括布袋过滤器、喷雾塔、湿式静电除尘、纳碱法、石膏法和选择性非催化还原(SNCR),用于减少制造过程中尤其是颗粒物(PM2.5 - PM10)、二氧化硫和氮氧化物的排放。
Classification
Class name : Hierarchy level
  • ILCD: Reference Parameters / Materials production / Glass and ceramics
General comment on data set the Technical of end-of-pipe management technology for pollution sulfur dioxideisDirect discharge
Copyright No
Owner of data set
Quantitative reference
Reference flow(s)
Technological representativeness
Technology description including background system the Technical of end-of-pipe management technology for pollution sulfur dioxideisDirect discharge
LCI method and allocation
Type of data set Unit process, single operation
Data sources, treatment and representativeness
Deviation from data treatment and extrapolations principles / explanations None
Data source(s) used for this data set
Completeness
Completeness of product model No statement
Validation
Type of review
Dependent internal review
Reviewer name and institution
Data generator
Data set generator / modeller
Publication and ownership
UUID 48a8131f-bc66-46ed-9d38-811bf545abe0
Date of last revision 2024-04-15T22:05:10.152144+08:00
Data set version 00.01.005
Permanent data set URI https://lcadata.tiangong.world/showProcess.xhtml?uuid=48a8131f-bc66-46ed-9d38-811bf545abe0&version=01.00.000&stock=TianGong
Owner of data set
Copyright No
License type Free of charge for all users and uses

Inputs

Outputs

Type of flow Classification Flow Location Mean amount Resulting amount Minimum amount Maximum amount
Product flow
Materials production / Glass and ceramics 1.0 m21.0 m2
General comment nan
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 1.08 kg1.08 kg
General comment the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isBag filter,Its Technical efficiency of end-of-pipe management99,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 16.2 kg16.2 kg
General comment the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isOthers (wet electrostatic precipitation),Its Technical efficiency of end-of-pipe management85,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 43.2 kg43.2 kg
General comment the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isSpray tower,Its Technical efficiency of end-of-pipe management60,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 72.0 kg72.0 kg
General comment the Technical of end-of-pipe management technology for pollution sulfur dioxideisOthers (sodium alkali method),Its Technical efficiency of end-of-pipe management70,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 96.0 kg96.0 kg
General comment the Technical of end-of-pipe management technology for pollution sulfur dioxideisLime/gypsum method,Its Technical efficiency of end-of-pipe management60,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 102.0 kg102.0 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen oxidesisSNCR,Its Technical efficiency of end-of-pipe management50,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 108.0 kg108.0 kg
General comment the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isDirect discharge
Product flow
Materials production / Inorganic chemicals 1200000.0 m31200000.0 m3
General comment the treatment technology for the pollution of Exhaust gasdidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 204.0 kg204.0 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen oxidesisDirect discharge,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 240.0 kg240.0 kg
General comment the Technical of end-of-pipe management technology for pollution sulfur dioxideisDirect discharge