Close Go back Collapse all sections
Process Data set: Blood products ; Blood ; Biochemical extraction process ; All sizes; NESPS2 (en) en zh

Key Data Set Information
Location CN
Reference year 2019
Name
Blood products ; Blood ; Biochemical extraction process ; All sizes; NESPS2
Use advice for data set This dataset is derived from the Pollution Source Census Report and contains information on pollution emissions and related products. However, it does not include data on energy or chemical consumption, nor does it provide information on waste or co-product generation. When utilizing this dataset, please supplement the missing data based on actual conditions before use
Technical purpose of product or process 血液制品的生化提取工艺在血液制品行业的所有生产规模中都有应用。该工艺可以包括各种末端处理技术以处理污染,特别是针对化学需氧量(COD)、有机结合氮、总磷和挥发性有机化合物(VOCs)。可以将物理化学处理与生物处理(如好氧、缺氧/好氧和厌氧方法)结合使用,以提高污染物管理的效率。这些处理对于最大限度地减少血液制品生产的环境影响和确保遵守废物管理规定至关重要。
Classification
Class name : Hierarchy level
  • ILCD: Reference Parameters / Materials production / Organic chemicals
General comment on data set the Technical of end-of-pipe management technology for pollution chemical oxygen demandisWithout terminal treatment technology,Its Technical efficiency of end-of-pipe management0,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual normal operating time of wastewater treatment facilities (hours) / annual normal production time of enterprises (hours)
Copyright No
Owner of data set
Quantitative reference
Reference flow(s)
Technological representativeness
Technology description including background system the Technical of end-of-pipe management technology for pollution chemical oxygen demandisWithout terminal treatment technology,Its Technical efficiency of end-of-pipe management0,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual normal operating time of wastewater treatment facilities (hours) / annual normal production time of enterprises (hours)
LCI method and allocation
Type of data set Unit process, single operation
Data sources, treatment and representativeness
Deviation from data treatment and extrapolations principles / explanations None
Data source(s) used for this data set
Completeness
Completeness of product model No statement
Validation
Type of review
Dependent internal review
Reviewer name and institution
Data generator
Data set generator / modeller
Publication and ownership
UUID 7d07a7b6-739d-42f8-a388-be08125ab2b1
Date of last revision 2024-04-15T22:07:14.696033+08:00
Data set version 00.01.005
Permanent data set URI https://lcadata.tiangong.world/showProcess.xhtml?uuid=7d07a7b6-739d-42f8-a388-be08125ab2b1&version=01.00.000&stock=TianGong
Owner of data set
Copyright No
License type Free of charge for all users and uses

Inputs

Outputs

Type of flow Classification Flow Location Mean amount Resulting amount Minimum amount Maximum amount
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 3.500000000000001E-4 kg3.500000000000001E-4 kg
General comment the Technical of end-of-pipe management technology for pollution phosphorus, totalisPhysicochemical treatment + anaerobic biological treatment + anoxic/aerobic biological treatment,Its Technical efficiency of end-of-pipe management99,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual normal operating time of waste gas treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 5.250000000000001E-4 kg5.250000000000001E-4 kg
General comment the Technical of end-of-pipe management technology for pollution phosphorus, totalisPhysicochemical treatment + anoxic/aerobic biological treatment,Its Technical efficiency of end-of-pipe management98.5,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual normal operating time of wastewater treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 8.049999999999991E-4 kg8.049999999999991E-4 kg
General comment the Technical of end-of-pipe management technology for pollution phosphorus, totalisPhysicochemical treatment + anaerobic hydrolysis + aerobic biological treatment,Its Technical efficiency of end-of-pipe management97.7,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual normal operating time of wastewater treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.00105 kg0.00105 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisPhysicochemical treatment + anoxic/aerobic biological treatment,Its Technical efficiency of end-of-pipe management95,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual normal operating time of waste gas treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.001225 kg0.001225 kg
General comment the Technical of end-of-pipe management technology for pollution phosphorus, totalisPhysicochemical treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management96.5,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual normal operating time of wastewater treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.0021 kg0.0021 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisOther,Its Technical efficiency of end-of-pipe management90,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual normal operating time of wastewater treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.002667000000000001 kg0.002667000000000001 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisPhysicochemical treatment + anaerobic biological treatment + anoxic/aerobic biological treatment,Its Technical efficiency of end-of-pipe management87.3,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual normal operating time of wastewater treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.003500000000000001 kg0.003500000000000001 kg
General comment the Technical of end-of-pipe management technology for pollution phosphorus, totalisOther,Its Technical efficiency of end-of-pipe management90,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual normal operating time of waste gas treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.003969000000000001 kg0.003969000000000001 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisPhysicochemical treatment + anaerobic hydrolysis + aerobic biological treatment,Its Technical efficiency of end-of-pipe management81.1,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual normal operating time of waste gas treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.004095000000000001 kg0.004095000000000001 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisPhysicochemical treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management80.5,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual normal operating time of waste gas treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.007649999999999999 kg0.007649999999999999 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen, organic boundisPhysicochemical treatment + anaerobic biological treatment + anoxic/aerobic biological treatment,Its Technical efficiency of end-of-pipe management85,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual normal operating time of wastewater treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.008517000000000002 kg0.008517000000000002 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen, organic boundisPhysicochemical treatment + anoxic/aerobic biological treatment,Its Technical efficiency of end-of-pipe management83.3,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual normal operating time of wastewater treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.0153 kg0.0153 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen, organic boundisOther,Its Technical efficiency of end-of-pipe management70,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual normal operating time of waste gas treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.018207 kg0.018207 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen, organic boundisPhysicochemical treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management64.3,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual normal operating time of waste gas treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.021 kg0.021 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisWithout terminal treatment technology,Its Technical efficiency of end-of-pipe management0,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual normal operating time of waste gas treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.02397 kg0.02397 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen, organic boundisPhysicochemical treatment + anaerobic hydrolysis + aerobic biological treatment,Its Technical efficiency of end-of-pipe management53,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual normal operating time of wastewater treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.0311 kg0.0311 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisRegenerative catalytic combustion method,Its Technical efficiency of end-of-pipe management99,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual normal operating time of waste gas treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.035 kg0.035 kg
General comment the Technical of end-of-pipe management technology for pollution phosphorus, totalisWithout terminal treatment technology,Its Technical efficiency of end-of-pipe management0,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual normal operating time of wastewater treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.03732000000000009 kg0.03732000000000009 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisAdsorption + steam desorption,Its Technical efficiency of end-of-pipe management98.8,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual normal operating time of waste gas treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.051 kg0.051 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen, organic boundisWithout terminal treatment technology,Its Technical efficiency of end-of-pipe management0,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual normal operating time of waste gas treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.05340000000000013 kg0.05340000000000013 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisPhysicochemical treatment + anaerobic biological treatment + anoxic/aerobic biological treatment,Its Technical efficiency of end-of-pipe management98.8,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual normal operating time of waste gas treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.2180500000000002 kg0.2180500000000002 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisPhysicochemical treatment + anaerobic hydrolysis + aerobic biological treatment,Its Technical efficiency of end-of-pipe management95.1,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual normal operating time of waste gas treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.2936999999999997 kg0.2936999999999997 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisPhysicochemical treatment + anoxic/aerobic biological treatment,Its Technical efficiency of end-of-pipe management93.4,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual normal operating time of waste gas treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.311 kg0.311 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisOther,Its Technical efficiency of end-of-pipe management90,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual normal operating time of waste gas treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.445 kg0.445 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisOther,Its Technical efficiency of end-of-pipe management90,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual normal operating time of wastewater treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.5384499999999998 kg0.5384499999999998 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisPhysicochemical treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management87.9,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual normal operating time of wastewater treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.7775 kg0.7775 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisCondensation,Its Technical efficiency of end-of-pipe management75,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual normal operating time of wastewater treatment facilities (hours) / annual normal production time of enterprises (hours)
Product flow
Use and consumption / Consumption of goods 1.0 kg1.0 kg
General comment nan
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 2.177 kg2.177 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisLow temperature plasma,Its Technical efficiency of end-of-pipe management30,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual normal operating time of waste gas treatment facilities (hours) / annual normal production time of enterprises (hours)
2.59 2.59
General comment the Technical of end-of-pipe management technology for pollution Waste wateris/,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual normal operating time of wastewater treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 3.11 kg3.11 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisWithout terminal treatment technology,Its Technical efficiency of end-of-pipe management0,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual normal operating time of waste gas treatment facilities (hours) / annual normal production time of enterprises (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 4.45 kg4.45 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisWithout terminal treatment technology,Its Technical efficiency of end-of-pipe management0,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = annual normal operating time of wastewater treatment facilities (hours) / annual normal production time of enterprises (hours)