Close Go back Collapse all sections
Process Data set: Polyester filament ; Polyester chips ; Chip spinning (slicing - drying - melting - spinning - winding) ; All sizes; NESPS2 (en) en zh

Key Data Set Information
Location CN
Reference year 2019
Name
Polyester filament ; Polyester chips ; Chip spinning (slicing - drying - melting - spinning - winding) ; All sizes; NESPS2
Use advice for data set This dataset is derived from the Pollution Source Census Report and contains information on pollution emissions and related products. However, it does not include data on energy or chemical consumption, nor does it provide information on waste or co-product generation. When utilizing this dataset, please supplement the missing data based on actual conditions before use
Technical purpose of product or process 所述工艺用于从聚酯切片通过切片纺丝工艺(包括切片、干燥、熔融、纺丝和卷绕)生产聚酯长丝。这些聚酯长丝适用于包括纺织、汽车和包装在内的各种行业,其中需要高强度合成纤维。
Classification
Class name : Hierarchy level
  • ILCD: Reference Parameters / Materials production / Plastics
General comment on data set the treatment technology for the pollution of Exhaust gasdidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Copyright No
Owner of data set
Quantitative reference
Reference flow(s)
Technological representativeness
Technology description including background system the treatment technology for the pollution of Exhaust gasdidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
LCI method and allocation
Type of data set Unit process, single operation
Data sources, treatment and representativeness
Deviation from data treatment and extrapolations principles / explanations None
Data source(s) used for this data set
Completeness
Completeness of product model No statement
Validation
Type of review
Dependent internal review
Reviewer name and institution
Data generator
Data set generator / modeller
Publication and ownership
UUID 7f770a7b-6e27-43fe-a92a-4faf2b698e8b
Date of last revision 2024-04-15T22:07:22.360056+08:00
Data set version 00.01.005
Permanent data set URI https://lcadata.tiangong.world/showProcess.xhtml?uuid=7f770a7b-6e27-43fe-a92a-4faf2b698e8b&version=01.00.000&stock=TianGong
Owner of data set
Copyright No
License type Free of charge for all users and uses

Inputs

Outputs

Type of flow Classification Flow Location Mean amount Resulting amount Minimum amount Maximum amount
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 2.01E-4 kg2.01E-4 kg
General comment the Technical of end-of-pipe management technology for pollution phosphorus, totalisPhysicochemical treatment + anaerobic biological treatment + aerobic biological treatment + physicochemical treatment,Its Technical efficiency of end-of-pipe management90,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 3.617999999999999E-4 kg3.617999999999999E-4 kg
General comment the Technical of end-of-pipe management technology for pollution phosphorus, totalisPhysicochemical treatment + anaerobic biological treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management82,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Product flow
Emissions / Other substance type 9.375E-4 kg9.375E-4 kg
General comment the Technical of end-of-pipe management technology for pollution Petroleum-related wasteisPhysicochemical treatment + anaerobic biological treatment + aerobic biological treatment + physicochemical treatment,Its Technical efficiency of end-of-pipe management85
Product flow
Materials production / Plastics 1000.0 kg1000.0 kg
General comment nan
1200.0 1200.0
General comment the treatment technology for the pollution of Waste waterdidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
0.0014256 0.0014256
General comment the Technical of end-of-pipe management technology for pollution Ammonia NitrogenisPhysicochemical treatment + anaerobic biological treatment + aerobic biological treatment + physicochemical treatment,Its Technical efficiency of end-of-pipe management78
0.0015551999999999999 0.0015551999999999999
General comment the Technical of end-of-pipe management technology for pollution Ammonia NitrogenisPhysicochemical treatment + anaerobic biological treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management76,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.00158 kg0.00158 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen, organic boundisPhysicochemical treatment + anaerobic biological treatment + aerobic biological treatment + physicochemical treatment,Its Technical efficiency of end-of-pipe management90,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Product flow
Emissions / Other substance type 0.0021875 kg0.0021875 kg
General comment the Technical of end-of-pipe management technology for pollution Petroleum-related wasteisPhysicochemical treatment + anaerobic biological treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management65,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.00237 kg0.00237 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen, organic boundisPhysicochemical treatment + anaerobic biological treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management85
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.003173 kg0.003173 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisAdsorption + steam desorption,Its Technical efficiency of end-of-pipe management62,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.003173 kg0.003173 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisDirect combustion,Its Technical efficiency of end-of-pipe management62,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.005678 kg0.005678 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisAbsorption + diversion,Its Technical efficiency of end-of-pipe management32
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.03096 kg0.03096 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisPhysicochemical treatment + anaerobic biological treatment + aerobic biological treatment + physicochemical treatment,Its Technical efficiency of end-of-pipe management97
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.0516 kg0.0516 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisPhysicochemical treatment + anaerobic biological treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management95,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
Product flow
Materials production / Inorganic chemicals 5567.0 m35567.0 m3
General comment the treatment technology for the pollution of Exhaust gasdidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /