Close Go back Collapse all sections
Process Data set: Woolen processing ; Washed clean gross ; Raw wool ; Wool scouring ; All sizes; NESPS2 (en) en zh

Key Data Set Information
Location CN
Reference year 2019
Name
Woolen processing ; Washed clean gross ; Raw wool ; Wool scouring ; All sizes; NESPS2
Use advice for data set This dataset is derived from the Pollution Source Census Report and contains information on pollution emissions and related products. However, it does not include data on energy or chemical consumption, nor does it provide information on waste or co-product generation. When utilizing this dataset, please supplement the missing data based on actual conditions before use
Technical purpose of product or process 所描述的工业过程适用于羊毛纺织行业,在该过程中,原毛经过洗涤清洁,为后续的制造步骤做准备。漂洗过程去除了羊毛中的油脂、污垢和汗渍。此过程的产出是准备好进一步加工成织物或其他羊毛制品的清洁羊毛。考虑到产生的污染物,应用废水处理技术来管理氨氮、化学需氧量(COD)、总磷和有机结合态氮。
Classification
Class name : Hierarchy level
  • ILCD: Reference Parameters / Materials production / Non-energetic raw materials
General comment on data set the Technical of end-of-pipe management technology for pollution chemical oxygen demandisChemical coagulation + anaerobic biological treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management98.34,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = operating time of treatment facilities (hours/year) / total production time (hours/year)
Copyright No
Owner of data set
Quantitative reference
Reference flow(s)
Technological representativeness
Technology description including background system the Technical of end-of-pipe management technology for pollution chemical oxygen demandisChemical coagulation + anaerobic biological treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management98.34,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = operating time of treatment facilities (hours/year) / total production time (hours/year)
LCI method and allocation
Type of data set Unit process, single operation
Data sources, treatment and representativeness
Deviation from data treatment and extrapolations principles / explanations None
Data source(s) used for this data set
Completeness
Completeness of product model No statement
Validation
Type of review
Dependent internal review
Reviewer name and institution
Data generator
Data set generator / modeller
Publication and ownership
UUID 91f27da7-555e-40d7-81e3-b305d54c3d2d
Date of last revision 2024-04-15T22:08:09.712411+08:00
Data set version 00.01.005
Permanent data set URI https://lcadata.tiangong.world/showProcess.xhtml?uuid=91f27da7-555e-40d7-81e3-b305d54c3d2d&version=01.00.000&stock=TianGong
Owner of data set
Copyright No
License type Free of charge for all users and uses

Inputs

Outputs

Type of flow Classification Flow Location Mean amount Resulting amount Minimum amount Maximum amount
Product flow
Materials production / Other materials 1000.0 kg1000.0 kg
General comment nan
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.002520590000000004 kg0.002520590000000004 kg
General comment the Technical of end-of-pipe management technology for pollution phosphorus, totalisChemical coagulation + anaerobic biological treatment + aerobic biological treatment + chemical treatment,Its Technical efficiency of end-of-pipe management98.3,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = operating time of treatment facilities (hours/year) / total production time (hours/year)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.015153194 kg0.015153194 kg
General comment the Technical of end-of-pipe management technology for pollution phosphorus, totalisChemical coagulation + anaerobic biological treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management89.78,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = operating time of treatment facilities (hours/year) / total production time (hours/year)
18.62 18.62
General comment the treatment technology for the pollution of Waste waterdidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = operating time of treatment facilities (hours/year) / total production time (hours/year)
0.2782231199999999 0.2782231199999999
General comment the Technical of end-of-pipe management technology for pollution Ammonia NitrogenisChemical coagulation + anaerobic biological treatment + aerobic biological treatment + chemical treatment,Its Technical efficiency of end-of-pipe management87.4,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = operating time of treatment facilities (hours/year) / total production time (hours/year)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.4417080479999999 kg0.4417080479999999 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen, organic boundisChemical coagulation + anaerobic biological treatment + aerobic biological treatment + chemical treatment,Its Technical efficiency of end-of-pipe management89.17,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = operating time of treatment facilities (hours/year) / total production time (hours/year)
0.4566392160000001 0.4566392160000001
General comment the Technical of end-of-pipe management technology for pollution Ammonia NitrogenisChemical coagulation + anaerobic biological treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management79.32,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = operating time of treatment facilities (hours/year) / total production time (hours/year)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.5807869439999999 kg0.5807869439999999 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen, organic boundisChemical coagulation + anaerobic biological treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management85.76,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = operating time of treatment facilities (hours/year) / total production time (hours/year)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 2.139705092000012 kg2.139705092000012 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisChemical coagulation + anaerobic biological treatment + aerobic biological treatment + chemical treatment,Its Technical efficiency of end-of-pipe management98.82,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = operating time of treatment facilities (hours/year) / total production time (hours/year)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 3.010093603999994 kg3.010093603999994 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisChemical coagulation + anaerobic biological treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management98.34,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = operating time of treatment facilities (hours/year) / total production time (hours/year)