Use advice for data set This dataset is derived from the Pollution Source Census Report and contains information on pollution emissions and related products. However, it does not include data on energy or chemical consumption, nor does it provide information on waste or co-product generation. When utilizing this dataset, please supplement the missing data based on actual conditions before use
Technical purpose of product or process 该数据集代表年产量大于等于200吨的兽用中成药液体制剂生产设施的废水处理过程。包含旨在减少化学需氧量、氨氮、总磷和有机结合氮等污染的尾端处理技术。适用于旨在确保环境合规和提高废水管理效率的设施。
Classification
Class name : Hierarchy level
  • ILCD: Reference Parameters / Other Services / Health
General comment on data set the Technical of end-of-pipe management technology for pollution chemical oxygen demandisAerobic biological treatment,Its Technical efficiency of end-of-pipe management65,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is K = normal operation time of wastewater treatment facility (hours/year) / normal production time of enterprises (hours/year)
Copyright No
Owner of data set
Quantitative reference
Reference flow(s)
Technological representativeness
Technology description including background system the Technical of end-of-pipe management technology for pollution chemical oxygen demandisAerobic biological treatment,Its Technical efficiency of end-of-pipe management65,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is K = normal operation time of wastewater treatment facility (hours/year) / normal production time of enterprises (hours/year)
LCI method and allocation
Type of data set Unit process, single operation
Data sources, treatment and representativeness
Deviation from data treatment and extrapolations principles / explanations None
Data source(s) used for this data set
Completeness
Completeness of product model No statement
Validation
Type of review
Dependent internal review
Reviewer name and institution
Data generator
Data set generator / modeller
Publication and ownership
UUID 99506d5e-ce37-47b4-8705-82fc67c7f8ae
Date of last revision 2024-04-15T22:08:22.667136+08:00
Data set version 00.01.005
Permanent data set URI https://lcadata.tiangong.world/showProcess.xhtml?uuid=99506d5e-ce37-47b4-8705-82fc67c7f8ae&version=01.00.000&stock=TianGong
Owner of data set
Copyright No
License type Free of charge for all users and uses

Inputs

Outputs

Type of flow Classification Flow Location Mean amount Resulting amount Minimum amount Maximum amount
Product flow
Materials production / Other materials 1000.0 kg1000.0 kg
General comment nan
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.0129 kg0.0129 kg
General comment the Technical of end-of-pipe management technology for pollution phosphorus, totalisAnaerobic biological treatment + aerobic biological treatment + physicochemical treatment,Its Technical efficiency of end-of-pipe management70,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = operating time of wastewater treatment facilities (hours) / annual normal production time of enterprise (hours)
0.017 0.017
General comment the Technical of end-of-pipe management technology for pollution Ammonia NitrogenisAnaerobic biological treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management75,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is K = normal operation time of wastewater treatment facility (hours/year) / normal production time of enterprises (hours/year)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.0172 kg0.0172 kg
General comment the Technical of end-of-pipe management technology for pollution phosphorus, totalisAerobic biological treatment + physical chemical treatment,Its Technical efficiency of end-of-pipe management60,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = opreating time of treatment facilities (hours/year) / normal production time (hours/year)
0.025840000000000002 0.025840000000000002
General comment the Technical of end-of-pipe management technology for pollution Ammonia NitrogenisAerobic biological treatment,Its Technical efficiency of end-of-pipe management62,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is K = normal operation time of wastewater treatment facility (hours/year) / normal production time of enterprises (hours/year)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.033280000000000004 kg0.033280000000000004 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen, organic boundisAnaerobic biological treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management74,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = operating time of wastewater treatment facilities (hours) / annual normal production time of enterprise (hours)
40600.0 40600.0
General comment the Technical of end-of-pipe management technology for pollution Waste wateris/,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is K = normal operation time of wastewater treatment facility (hours/year) / normal production time of enterprises (hours/year)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.0512 kg0.0512 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen, organic boundisAerobic biological treatment,Its Technical efficiency of end-of-pipe management60,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = operating time of wastewater treatment facilities (hours) / annual normal production time of enterprise (hours)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.30528 kg0.30528 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisAnaerobic biological treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management84,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is K = normal operation time of wastewater treatment facility (hours/year) / normal production time of enterprises (hours/year)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 0.6678 kg0.6678 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisAerobic biological treatment,Its Technical efficiency of end-of-pipe management65,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is K = normal operation time of wastewater treatment facility (hours/year) / normal production time of enterprises (hours/year)