Process Data set: Raw material firing ; Other calcined refractory materials ; Refractory raw materials, gas fuel ; Furnaces for refractory materials (calcining kilns, including tunnel kilns, rotary kilns and shaft kilns) ; All sizes; NESPS2 (en) en zh

Key Data Set Information
Location CN
Reference year 2019
Name
Raw material firing ; Other calcined refractory materials ; Refractory raw materials, gas fuel ; Furnaces for refractory materials (calcining kilns, including tunnel kilns, rotary kilns and shaft kilns) ; All sizes; NESPS2
Use advice for data set This dataset is derived from the Pollution Source Census Report and contains information on pollution emissions and related products. However, it does not include data on energy or chemical consumption, nor does it provide information on waste or co-product generation. When utilizing this dataset, please supplement the missing data based on actual conditions before use
Technical purpose of product or process 所描述的工业过程用于耐火原料的煅烧,以生产各种煅烧耐火材料。这些材料通常用于高温应用,如用于炉子、窑、焚烧炉和反应堆的内衬。该过程利用不同类型的煅烧窑,包括适合各种生产规模的隧道窑、回转窑和竖窑。该数据集可能代表这些材料生产的环境影响,考虑了控制颗粒物(PM2.5 - PM10)、二氧化硫和氮氧化物排放的污染控制技术,如布袋过滤器、石膏/石灰法和选择性非催化还原(SNCR)。
Classification
Class name : Hierarchy level
  • ILCD: Reference Parameters / Energy carriers and technologies / Heat and steam
General comment on data set the treatment technology for the pollution of Exhaust gasdidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
Copyright No
Owner of data set
Quantitative reference
Reference flow(s)
Technological representativeness
Technology description including background system the treatment technology for the pollution of Exhaust gasdidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
LCI method and allocation
Type of data set Unit process, single operation
Data sources, treatment and representativeness
Deviation from data treatment and extrapolations principles / explanations None
Data source(s) used for this data set
Completeness
Completeness of product model No statement
Validation
Type of review
Dependent internal review
Reviewer name and institution
Data generator
Data set generator / modeller
Publication and ownership
UUID bf31ad56-de1a-4ab7-865c-f863d8f8f385
Date of last revision 2024-04-15T22:10:00.631815+08:00
Data set version 00.01.005
Permanent data set URI https://lcadata.tiangong.world/showProcess.xhtml?uuid=bf31ad56-de1a-4ab7-865c-f863d8f8f385&version=01.00.000&stock=TianGong
Owner of data set
Copyright No
License type Free of charge for all users and uses

Inputs

Outputs

Type of flow Classification Flow Location Mean amount Resulting amount Minimum amount Maximum amount
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.0036 kg0.0036 kg
General comment the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isBag filter,Its Technical efficiency of end-of-pipe management99,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.36 kg0.36 kg
General comment the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isDirect discharge,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.884 kg0.884 kg
General comment the Technical of end-of-pipe management technology for pollution sulfur dioxideisLimestone/gypsum method,Its Technical efficiency of end-of-pipe management60,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.94 kg0.94 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen oxidesisSNCR,Its Technical efficiency of end-of-pipe management50,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Product flow
Materials production / Other mineralic materials 1000.0 kg1000.0 kg
General comment nan
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 1.88 kg1.88 kg
General comment the Technical of end-of-pipe management technology for pollution Nitrogen oxidesisDirect discharge,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 2.21 kg2.21 kg
General comment the Technical of end-of-pipe management technology for pollution sulfur dioxideisDirect discharge
Product flow
Materials production / Inorganic chemicals 5134.0 m35134.0 m3
General comment the treatment technology for the pollution of Exhaust gasdidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)