Close Go back Collapse all sections
Process Data set: Printing ; Printed products (substrate is plastic) ; Solvent-based gravure Ink ; Gravure printing ; All sizes; NESPS2 (en) en zh

Key Data Set Information
Location CN
Reference year 2019
Name
Printing ; Printed products (substrate is plastic) ; Solvent-based gravure Ink ; Gravure printing ; All sizes; NESPS2
Use advice for data set This dataset is derived from the Pollution Source Census Report and contains information on pollution emissions and related products. However, it does not include data on energy or chemical consumption, nor does it provide information on waste or co-product generation. When utilizing this dataset, please supplement the missing data based on actual conditions before use
Technical purpose of product or process 所描述的工业过程涉及到塑料基材上的凹版印刷品的生产。在整个操作规模中,使用溶剂型凹版油墨进行印刷。数据集指出了印刷行业中的应用,特别是在塑料表面创建高质量印刷材料的场合。此外,过程中涉及到挥发性有机化合物(VOCs)排放引发的污染管理,必须使用尾端处理设施来减少环境影响。
Classification
Class name : Hierarchy level
  • ILCD: Reference Parameters / Systems / Other systems
General comment on data set the treatment technology for the pollution of volatile organic compounddidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Copyright No
Owner of data set
Quantitative reference
Reference flow(s)
Technological representativeness
Technology description including background system the treatment technology for the pollution of volatile organic compounddidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
LCI method and allocation
Type of data set Unit process, single operation
Data sources, treatment and representativeness
Deviation from data treatment and extrapolations principles / explanations None
Data source(s) used for this data set
Completeness
Completeness of product model No statement
Validation
Type of review
Dependent internal review
Reviewer name and institution
Data generator
Data set generator / modeller
Publication and ownership
UUID d0861ea8-4a97-41b6-8684-02fab5116c91
Date of last revision 2024-04-15T22:10:42.830698+08:00
Data set version 00.01.005
Permanent data set URI https://lcadata.tiangong.world/showProcess.xhtml?uuid=d0861ea8-4a97-41b6-8684-02fab5116c91&version=01.00.000&stock=TianGong
Owner of data set
Copyright No
License type Free of charge for all users and uses

Inputs

Type of flow Classification Flow Location Mean amount Resulting amount Minimum amount Maximum amount
Product flow
Systems / Paints and chemical preparations 1000.0 kg1000.0 kg
General comment nan

Outputs

Type of flow Classification Flow Location Mean amount Resulting amount Minimum amount Maximum amount
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 39.0 kg39.0 kg
General comment the treatment technology for the pollution of volatile organic compounddidn't offered,Its Technical efficiency of end-of-pipe management94,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 65.0 kg65.0 kg
General comment the treatment technology for the pollution of volatile organic compounddidn't offered,Its Technical efficiency of end-of-pipe management90,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 97.5 kg97.5 kg
General comment the treatment technology for the pollution of volatile organic compounddidn't offered,Its Technical efficiency of end-of-pipe management85
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 97.5 kg97.5 kg
General comment the treatment technology for the pollution of volatile organic compounddidn't offered,Its Technical efficiency of end-of-pipe management85,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 227.5 kg227.5 kg
General comment the treatment technology for the pollution of volatile organic compounddidn't offered,Its Technical efficiency of end-of-pipe management65,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 305.5 kg305.5 kg
General comment the treatment technology for the pollution of volatile organic compounddidn't offered,Its Technical efficiency of end-of-pipe management53,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 396.5 kg396.5 kg
General comment the treatment technology for the pollution of volatile organic compounddidn't offered,Its Technical efficiency of end-of-pipe management39,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 429.0 kg429.0 kg
General comment the treatment technology for the pollution of volatile organic compounddidn't offered,Its Technical efficiency of end-of-pipe management34,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 539.5 kg539.5 kg
General comment the treatment technology for the pollution of volatile organic compounddidn't offered,Its Technical efficiency of end-of-pipe management17
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 539.5 kg539.5 kg
General comment the treatment technology for the pollution of volatile organic compounddidn't offered,Its Technical efficiency of end-of-pipe management17,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 552.5 kg552.5 kg
General comment the treatment technology for the pollution of volatile organic compounddidn't offered,Its Technical efficiency of end-of-pipe management15,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 572.0 kg572.0 kg
General comment the treatment technology for the pollution of volatile organic compounddidn't offered,Its Technical efficiency of end-of-pipe management12
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 650.0 kg650.0 kg
General comment the treatment technology for the pollution of volatile organic compounddidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /