Close Go back Collapse all sections
Process Data set: Polyvinyl alcohol water soluble fibers ; Polyvinyl alcohol ; Dope preparation - spinning - heat treatment - post treatment ; All sizes; NESPS2 (en) en zh

Key Data Set Information
Location CN
Reference year 2019
Name
Polyvinyl alcohol water soluble fibers ; Polyvinyl alcohol ; Dope preparation - spinning - heat treatment - post treatment ; All sizes; NESPS2
Use advice for data set This dataset is derived from the Pollution Source Census Report and contains information on pollution emissions and related products. However, it does not include data on energy or chemical consumption, nor does it provide information on waste or co-product generation. When utilizing this dataset, please supplement the missing data based on actual conditions before use
Technical purpose of product or process 通过所描述的工业过程生产的聚乙烯醇水溶性纤维通常用于生产纺织品和包装薄膜,因为它们具有水溶性和生物可降解性质。提到的末端处理技术,包括各种物理化学和生物处理,用于处理制造设施的废水和排放物,控制污染指标,如氨氮、化学需氧量、总磷、总氮、石油相关废气和挥发性有机化合物(VOCs),确保这些设施符合环境法规。
Classification
Class name : Hierarchy level
  • ILCD: Reference Parameters / Materials production / Plastics
General comment on data set the Technical of end-of-pipe management technology for pollution chemical oxygen demandisPhysicochemical treatment + anaerobic biological treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management90,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
Copyright No
Owner of data set
Quantitative reference
Reference flow(s)
Technological representativeness
Technology description including background system the Technical of end-of-pipe management technology for pollution chemical oxygen demandisPhysicochemical treatment + anaerobic biological treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management90,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
LCI method and allocation
Type of data set Unit process, single operation
Data sources, treatment and representativeness
Deviation from data treatment and extrapolations principles / explanations None
Data source(s) used for this data set
Completeness
Completeness of product model No statement
Validation
Type of review
Dependent internal review
Reviewer name and institution
Data generator
Data set generator / modeller
Publication and ownership
UUID d1344fa9-0f76-4b0d-8c54-e0008443ab6e
Date of last revision 2024-04-15T22:10:44.254302+08:00
Data set version 00.01.005
Permanent data set URI https://lcadata.tiangong.world/showProcess.xhtml?uuid=d1344fa9-0f76-4b0d-8c54-e0008443ab6e&version=01.00.000&stock=TianGong
Owner of data set
Copyright No
License type Free of charge for all users and uses

Inputs

Outputs

Type of flow Classification Flow Location Mean amount Resulting amount Minimum amount Maximum amount
Product flow
Materials production / Organic chemicals 1000.0 kg1000.0 kg
General comment nan
Product flow
Emissions / Inorganic covalent compounds 0.00514 kg0.00514 kg
General comment the Technical of end-of-pipe management technology for pollution TotalPhosphorusisPhysicochemical treatment + anaerobic biological treatment + aerobic biological treatment + physicochemical treatment,Its Technical efficiency of end-of-pipe management90,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.0076266 kg0.0076266 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisAdsorption + steam desorption,Its Technical efficiency of end-of-pipe management62,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = 2
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.0076266 kg0.0076266 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisDirect combustion,Its Technical efficiency of end-of-pipe management62,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = operating time of wastewater treatment facilities (days/year) / production time (days/year)
Product flow
Emissions / Inorganic covalent compounds 0.009252 kg0.009252 kg
General comment the Technical of end-of-pipe management technology for pollution TotalPhosphorusisPhysicochemical treatment + anaerobic biological treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management82,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
0.00934 0.00934
General comment the Technical of end-of-pipe management technology for pollution Total NitrogenisPhysicochemical treatment + anaerobic biological treatment + aerobic biological treatment + physicochemical treatment,Its Technical efficiency of end-of-pipe management90,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
0.010934 0.010934
General comment the Technical of end-of-pipe management technology for pollution Ammonia NitrogenisPhysicochemical treatment + anaerobic biological treatment + aerobic biological treatment + physicochemical treatment,Its Technical efficiency of end-of-pipe management78,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
0.011928000000000001 0.011928000000000001
General comment the Technical of end-of-pipe management technology for pollution Ammonia NitrogenisPhysicochemical treatment + anaerobic biological treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management76,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.013647600000000001 kg0.013647600000000001 kg
General comment the Technical of end-of-pipe management technology for pollution volatile organic compoundisAbsorption + diversion,Its Technical efficiency of end-of-pipe management32,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = operating time of wastewater treatment facilities (days/year) / production time (days/year)
0.01401 0.01401
General comment the Technical of end-of-pipe management technology for pollution Total NitrogenisPhysicochemical treatment + anaerobic biological treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management85,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
Product flow
Emissions / Other substance type 0.02355 kg0.02355 kg
General comment the Technical of end-of-pipe management technology for pollution Petroleum-related waste gasisPhysicochemical treatment + anaerobic biological treatment + aerobic biological treatment + physicochemical treatment,Its Technical efficiency of end-of-pipe management85,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = 2
28550.0 28550.0
General comment the treatment technology for the pollution of Waste waterdidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
Product flow
Emissions / Other substance type 0.054950000000000006 kg0.054950000000000006 kg
General comment the Technical of end-of-pipe management technology for pollution Petroleum-related waste gasisPhysicochemical treatment + anaerobic biological treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management65,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 1.173 kg1.173 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisPhysicochemical treatment + anaerobic biological treatment + aerobic biological treatment + physicochemical treatment,Its Technical efficiency of end-of-pipe management97,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)
Product flow
Materials production / Inorganic chemicals 2355.0 m32355.0 m3
General comment the treatment technology for the pollution of Exhaust gasdidn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = 2
Elementary flow
Emissions / Emissions to water / Emissions to water, unspecified 3.91 kg3.91 kg
General comment the Technical of end-of-pipe management technology for pollution chemical oxygen demandisPhysicochemical treatment + anaerobic biological treatment + aerobic biological treatment,Its Technical efficiency of end-of-pipe management90,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is k = power consumption of wastewater treatment facilities (kWh/year) / operating time of wastewater treatment facilities (hours/year) / total power of wastewater treatment facilities (kW)