Close Go back Collapse all sections
Process Data set: Pretreatment ; Metal Furniture ; Water, reagent, welding rod, compressed gas ; Cleaning, surface treatment, machining (cutting, welding, drilling) ; All sizes; NESPS2 (en) en zh

Key Data Set Information
Location CN
Reference year 2019
Name
Pretreatment ; Metal Furniture ; Water, reagent, welding rod, compressed gas ; Cleaning, surface treatment, machining (cutting, welding, drilling) ; All sizes; NESPS2
Use advice for data set This dataset is derived from the Pollution Source Census Report and contains information on pollution emissions and related products. However, it does not include data on energy or chemical consumption, nor does it provide information on waste or co-product generation. When utilizing this dataset, please supplement the missing data based on actual conditions before use
Technical purpose of product or process 该数据集描述了金属家具制造的预处理过程,涉及使用水和试剂清洗、使用焊条和压缩气体焊接以及包括切割、焊接和打孔在内的机加工操作。该过程适用于所有规模的生产。此数据对于准确评估金属家具生产的环境影响至关重要。
Classification
Class name : Hierarchy level
  • ILCD: Reference Parameters / Materials production / Metals and semimetals
General comment on data set the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isDirect discharge,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Copyright No
Owner of data set
Quantitative reference
Reference flow(s)
Technological representativeness
Technology description including background system the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isDirect discharge,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
LCI method and allocation
Type of data set Unit process, single operation
Data sources, treatment and representativeness
Deviation from data treatment and extrapolations principles / explanations None
Data source(s) used for this data set
Completeness
Completeness of product model No statement
Validation
Type of review
Dependent internal review
Reviewer name and institution
Data generator
Data set generator / modeller
Publication and ownership
UUID d4982043-05fe-4e1a-ab68-3401ca3f302d
Date of last revision 2024-04-15T22:10:49.737751+08:00
Data set version 00.01.005
Permanent data set URI https://lcadata.tiangong.world/showProcess.xhtml?uuid=d4982043-05fe-4e1a-ab68-3401ca3f302d&version=01.00.000&stock=TianGong
Owner of data set
Copyright No
License type Free of charge for all users and uses

Inputs

Outputs

Type of flow Classification Flow Location Mean amount Resulting amount Minimum amount Maximum amount
41.00000000000001 41.00000000000001
General comment the treatment technology for the pollution of Water (river water from technosphere, waste water)didn't offered,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Product flow
Materials production / Other materials 1.0 m21.0 m2
General comment nan
Product flow
Emissions / Other substance type 0.0034300000000000003 kg0.0034300000000000003 kg
General comment the Technical of end-of-pipe management technology for pollution Chemical Oxygen DemandisChemical coagulation + floating separation + A2/O process + precipitation separation,Its Technical efficiency of end-of-pipe management90,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.005 kg0.005 kg
General comment the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isBag filter,Its Technical efficiency of end-of-pipe management90,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.005 kg0.005 kg
General comment the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isOthers (filter element + cyclone),Its Technical efficiency of end-of-pipe management90,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.01 kg0.01 kg
General comment the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isSingle cylinder (multiple cylinders in parallel) cyclone,Its Technical efficiency of end-of-pipe management80,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Product flow
Materials production / Inorganic chemicals 20.8 m320.8 m3
General comment the Technical of end-of-pipe management technology for pollution Exhaust gasis/,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Product flow
Emissions / Other substance type 0.0343 kg0.0343 kg
General comment the Technical of end-of-pipe management technology for pollution Chemical Oxygen DemandisDirect discharge,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /
Elementary flow
Emissions / Emissions to air / Emissions to air, unspecified 0.05 kg0.05 kg
General comment the Technical of end-of-pipe management technology for pollution particles (PM2.5 - PM10)isDirect discharge,The formula for calculating the actual operation rate (k-value) of the end-of-pipe treatment facility is /