Data set: Electricity production ; Thermal power ; Zhejiang (00.01.005)

Full name
Electricity production ; Thermal power ; Zhejiang
Location
ZJ-CN
Reference year
2019
Valid until
Reference flow(s)
Type
Unit process, single operation
Parameterized?
no
LCIA results included?
no
Category
Unit processes / Energy carriers and technologies / Electricity
Synonyms
Use advice for data set
Users should adhere to the methodology outlined in the 'Enterprise Greenhouse Gas Emissions Accounting Methods and Reporting Guidelines for Power Generation Facilities' when utilizing this data set. It is important to consider that the data set does not include upstream raw material extraction and processing, nor downstream power consumption. Given that the statistics are based on 2019 figures, users must be cautious when applying the data to future scenarios or different time frames. Adjustments may be necessary to account for technological developments or changes in fuel mix. The given CO2 emission factors are calculated using fuel parameters specific to the year and region covered in the data set.
Data set use approval
General comment
Thermal power generation includes seventeen fossil fuels such as raw coal, washed coal, oil and natural gas. The process only considers the direct power generation process, not the upstream raw material extraction and processing and the downstream power consumption
LCI Method Principle
LCI Method Approaches
No records found.
Completeness of product model
No statement
Reviews
  • Dependent internal review by
License and access conditions
Copyright
no
License type
Free of charge for all users and uses
Owner of data set
Tiangong LCI Data Working Group
Technical purpose
The described industrial process pertains to thermal power generation in Zhejiang, China, utilizing a variety of fossil fuels such as raw coal, washed coal, oil, and natural gas for the production of electricity. The data set focuses on the direct electricity generation stage and is suitable for application in life cycle assessments of electric power produced by thermal power stations in the Zhejiang region.
Input Products
No records found.
Co-Products
No records found.
Data set version
00.01.005
Time stamp (last saved)
2024-03-28T01:19:39+08:00